Sleep Mode: This operation can only be selected when in Cooling Mode.

•  Press the “Sleep” button when in cool mode, the fan will automatically turn down to low fan speed. 
   The appliance will then operate the following sequence: 
•  The set temperature will increase by 1°C after 1 hour, then increase by 2°C after 2 hours.  
  After 6 hours the appliance will automatically switch off.

WATER DRAINAGE

 
This appliance is an advanced self-evaporating air conditioner, which reduces the need to empty the 
water tank in cooling mode. If the unit is vented correctly most of the water is reused to cool the 
condenser coils and any excess is evaporated. Please make sure that the rubber caps are firmly secured 
on the water drainage points when the unit is running. In extreme humidity or while the unit is in reverse 
heating mode, the internal water tank may fill quicker triggering the tank full alarm. When this occurs, the 
display panel will show an Error Code: E4 – this indicates you will need to manually drain the water tank.
               

Manual Drainage:

•   When the internal water tank is full – Error code: E4 will be displayed on the control panel and  
  the unit will stop working
•  Turn off the unit and unplug from the mains socket
•  Place the water drainage hose into a suitable container
•  Remove the rubber cap from the drain point
•  Insert the drainage hose in to the hole
•  Water will drain into container
•  After the tank has been fully drained, remove the pipe and insert the rubber cap back into the  
  drain point
 

Continuous Drainage:

•   Turn off the unit and unplug from the mains socket
•   Place the water drainage hose into a suitable container or over a drain
•   Remove the rubber cap from the secondary drain point
•   Insert the drainage hose in to the hole
•   Once appliance is switched on, water will continuously drip from drainage hose

Note: Please be mindful that if you are using a container, you will need to manually empty the container 

at regular intervals to ensure it doesn’t overfill.

Note: Please do not use continuous drainage if you intend to use the self-evaporating facility, for 

improved cooling effect.

Summary of Contents for IG9901

Page 1: ...fully before use and retain for future reference Before switching on your appliance always check for any damage which may have been caused in transit IG9901 9000 BTU 3 in 1 Air Conditioner IG9904 7000...

Page 2: ...ualified electrician 3 Make sure the unit is connected to an earthed power supply of the correct rating Please refer to the rating label located at the side of the unit 4 Leave the unit to stand for 1...

Page 3: ...es have passed since being turned off This prevents damage to the compressor 18 Do not let chemical substances come into contact with the appliance 19 It is not recommended to use flammable substances...

Page 4: ...300 m h 300 m h Power Supply 220 240V 50Hz 220 240V 50Hz Compressor Rotary Rotary Refrigerant R410A R410A Fan Speeds 3 3 Timer 24 Hour 24 Hour Operating Temperature 15 31 C 15 31 C Energy Rated Class...

Page 5: ...nd Air Outlet 3 Remote Control Sensor 4 Remote Control 5 Handle 6 Exhaust Hose assembly 7 Filters and Air Inlets 8 Drain Point 9 Secondary Drain Point 10 Water Drainage Hose Exhaust Assembly Front Bac...

Page 6: ...les located on either side and carefully lift until it slides out of the foam base Install the exhaust hose assembly onto the unit before switching on Installing Exhaust Hose Extend the exhaust hose b...

Page 7: ...urces to ensure adequate air circulation The exhaust hose can be extended from 30cm to 150cm but it is recommended to use as short as possible as this will minimise the escape of any expelled air and...

Page 8: ...rrectly plug into a wall socket the appliance will beep once Press the On Off button to switch on the appliance the LED Display will illuminate showing the ambient room temperature the louvers will op...

Page 9: ...ired room temperature the compressor will operate When the ambient room temperature is lower than the desired room temperature the compressor will stop and the fan will operate at the selected speed F...

Page 10: ...st operating function and mode Turning On Once the appliance has been installed correctly plug into a wall socket the appliance will beep once Press the On Off button to switch on the appliance the LE...

Page 11: ...ditioning mode activated When the ambient room temperature is higher than the desired room temperature the compressor will operate When the ambient room temperature is lower than the desired room temp...

Page 12: ...r Code E4 this indicates you will need to manually drain the water tank Manual Drainage When the internal water tank is full Error code E4 will be displayed on the control panel and the unit will stop...

Page 13: ...ide of the unit Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt and then wash the air filters by immersing them in lukewarm water with a neutral detergent Note Extreme car...

Page 14: ...temperature the unit will automatically switch off you can lower the set temperature to restart Check if air outlet is blocked if so remove obstacle Check if Timer function has been activated Water is...

Page 15: ...health and the environment The crossed out wheeled bin symbol on the product reminds you of your obligation that when you dispose of the appliance it must be separately collected Consumers should cont...

Page 16: ...16...

Page 17: ...17...

Page 18: ...over accessories or consumable parts that require replacement under normal use This includes shelving dials filters belts and trays etc In the unlikely event of a breakdown please refer to the Trouble...

Page 19: ...ble on our website www igenix co uk To register your product please complete all sections of the form below and return to us at the following address lgenix 38 Bluestem Road Ransomes Europark Ipswich...

Page 20: ...claimer Igenix operate a policy of continual improvement and development We therefore reserve the right to change alter the specification and appearance of our appliances without prior notice All diag...

Reviews: