32
12. Case of damage
Provide security in the danger zone.
Severe burns and scalding’s on the whole body are possible!
•
Check if no further steam escapes at the damaged place.
•
Set boiler pressureless!
Close valves as follows:
•
Close shutoff device without self-closing ball on steam and water holding stud.
•
Close shutoff device with self-closing ball on steam and water holding stud.
•
Slowly open drain valve. Level gauge becomes pressureless and water is drained.
•
For commissioning with new spare parts see chapter 10.3.
13. Spare parts
Always indicate article no. and serial no. (indicated on the identification plate) in case of
spare parts order!
13.1 Transparent level gauge
n = number of sight openings
Swivel connection
Pos.
no
.
Designation
Quan
tity
Article-no.
Size
5
6
7
8
9
10
11
15
Plug screw
1
40-00316
16
Sealing
1
40-00114
17
Clamping nut G5/8"
2
25-00047
18
Sealing
2
40-00110
19
Upper connecting
piece M12/32
1
25-00806
20
Lower connecting
piece M12/32
1
25-03886
21
Clamping nut G½"
1
25-00046
Fixed connection
Pos.
no
.
Designation
Quan
tity
Article-no.
Size
5
6
7
8
5
10
11
15
Plug screw
1
40-00316
16
Sealing
1
40-00114
21
Clamping nut G½"
1
25-00046
Danger