10
3. Important information
The direct water level gauge is for measurement and control purposes and
must only be used to display fill levels on a tank. Here care must be taken
that pressure and temperature do not exceed the maximum limitations of
use. These can be found on the identification plate.
The operator of the direct water level gauge is responsible for the intended
use of the indicator.
With the “offset” version adequate support (e.g. by spring suspension
elements etc.) must be provided to the device at the customer’s premises.
This can be fastened to the “transport unit”.
3.1 Intended use
Transparent level gauge
:
The transparent level gauge type mica is a direct water level gauge with illumination which
can be used for steam boilers and containers.
This product is in accordance to EU-directive 2014/68/EU. Applied policy acc. to DIN EN 13445
and ASME Boiler and Pressure Vessel Code. Considered regulations AD2000.
Furthermore,
this product meets the requirements of the standards DIN EN 12952-7 and DIN EN 12953-6
as a plant component for large water room boilers and water tube boilers.
4. Explanations
4.1 System description
The transparent level gauge in different versions is used to detect the water level of steam
generators or containers.
4.2 Function
The level gauge works according to the physical law of the communicating tubes. The water
level is visible due to the illumination of the water-steam space from the back. In the sight
opening, the water level is visible at the interface between water and steam.
Caution
Caution
Caution