background image

SCREEN

SCREEN

UP

DOWN

PC

P   Y   W

DISPLAY

SCREEN

+24V

+24V

B

NC

B

V+

V+

A

COMM

A

4-20mA

4-20mA

0V

NO

0V

1  2  3  4  5

TOC-30 INPUTS/OUTPUTS

International Gas Detectors

Note when removing cover for 
interface wiring, disconnect by 
carefully unplugging the 10 way 
ribbon cable.
DO NOT PLUG OR UNPLUG 
WHEN POWERED

E-Stop Option

Switch Option

Colour LCD

20mm Cable Entries
IGD Quick Fit Gland
Option PN 
Pack of 5

Optional Pellistor Port 
(IGD MK6 & MK7 Sensors)

Front Panel Ribbon Cable

Programming 
& Diagnostic Interface

Solid State Output

Solid State Input

PC Programming 
Port, Requires 
PC Running IGD 
Configurator 
Software

Addressable
Highway in/out

SPCO
Relay

Summary of Contents for TOC-30A-AN1

Page 1: ...d M a n t e n a n c e V 1 0 2 OLIVER IGD CO H S 2 CO2 SO2 NO NO2 CH4 International Gas Detectors Pepper Road Bramhall T echnology Park Stockport SK7 5BW England T el 44 0 161 483 1415 Fax 44 0 161 484...

Page 2: ...he digital inputs to interface with other systems such as fire alarms As with detectors in the TOC 30 series the annunciators will interface with any IGD addressable control panel TOC 30 Annunciators...

Page 3: ...ge Communication Relay Digital Output Digital Input Pellistor Port Sounder Display ABS IP65 using suitable glanding 0 95 RH Non Condensing 0 55 Deg C 12 28V DC RS485 IGD Data Highway 24V 0V A B 4 Core...

Page 4: ...refully unplugging the 10 way ribbon cable DO NOT PLUG OR UNPLUG WHEN POWERED E Stop Option Switch Option Colour LCD 20mm Cable Entries IGD Quick Fit Gland Option PN Pack of 5 Optional Pellistor Port...

Page 5: ...ves boiler shut down interfaces or similar When switching external loads it is important to consider the nature of the load being switched For inductive loads suitable protection from induced back EMF...

Page 6: ...lease the DOWN button and the new Base Address is Now Set Note That the Left LED Will Now be Flashing if the Annunciator is Communicating With its Control Panel 4100 4108 4116 4124 4101 4109 4117 4125...

Page 7: ...l panel then the following alternating message will be displayed SYSTEM STATUS SYSTEM STATUS SYSTEM STATUS SYSTEM STATUS SYSTEM STATUS SYSTEM STATUS SYSTEM STATUS SYSTEM STATUS Estop add 4101 al2 add...

Page 8: ...RESSES YOU CANNOT HAVE TWO DEVICE ADDRESSES SET THE SAME ON THE SAME ADDRESSABLE HIGHWAY IGD addressable systems use a 4 core cable or highway to connect all system devices Typically an addressable hi...

Page 9: ...the Gas Supply Device Annunciator E Stop Base Address Annunciator Digital Input TOC 10 Annunciator Sounder Display Annunciator Relay TOC 30A PHC Flammable Gas Detector Address 4101 4103 4201 4202 4110...