POC2502 Series User Manual
33
Connect the Fiber Cable
1.
Insert the duplex LC connector into the SFP transceiver.
2.
Connect the other end of the cable to a device with SFP transceiver installed.
3.
Check the LNK/ACT LED of the SFP slot on the front of the POC Managed Switch. Ensure that the SFP transceiver is
operating correctly.
4.
Check the Link mode of the SFP port if the link fails. To function with some fiber-NICs or media converters, user has to set
the port Link mode to
“1000 Force”
or
“100 Force”
.
Remove the Transceiver Module
1.
Make sure there is no network activity anymore.
2.
Remove the fiber-optic cable gently.
3.
Lift up the lever of the MGB module and turn it to a horizontal position.
4.
Pull out the module gently through the lever.
Figure 2-1-8
How to Pull Out the SFP Transceiver
Never pull out the module without lifting up the lever of the module and turning it into a horizontal
position. Directly pulling out the module could damage the module and the SFP module slot of the
POC Managed Switch.
2.2.4 Installing the Long Reach PoE Communication
The sections describe how to insert a coaxial cable into a BNC female port. You can plug in and out the coaxial cable to/from
any BNC female port port without having to power down the POC Managed Switch.
Approved IFS Long Reach PoE Extenders
The following list of approved IFS Long Reach PoE extenders is correct at the time of publication:
Long Reach Ethernet Coaxial Extenders
POC252-1CX-1P
1-Port 10/100TX PoE PSE + 1-Port Coax Long Reach PoE Extender
It is recommended to use IFS Long Reach Ethernet coaxial extenders on the POC Managed
Switch. If you insert a coaxial extender that is not supported, the POC Managed Switch may
damage it.
Summary of Contents for POC2502 Series
Page 1: ...1 POC2502 Series User Manual P N 1073045 REV B ISS 18MAY22...
Page 4: ...POC2502 Series User Manual 1...
Page 142: ...POC2502 Series User Manual 139 VLAN ID 3 Port 4 5 Untagged Port 6 7 Tagged Port 1 3 Excluded...
Page 283: ...POC2502 Series User Manual 280 Figure 4 10 7 IP based ACE Page Screenshot...
Page 347: ...POC2502 Series User Manual 344 No packet loss will occur...