Device manual 

Diagnostic unit  

with EtherNet/IP interface 

for vibration sensors

VSE151

80270598/00

  

03/2019

UK

Summary of Contents for VSE151

Page 1: ...Device manual Diagnostic unit with EtherNet IP interface for vibration sensors VSE151 80270598 00 03 2019 UK...

Page 2: ...object class code 0x01 15 8 4 2 Message router object class code 0x02 16 8 4 3 Assembly object class code 0x04 16 8 4 4 Connection manager object class code 0x06 16 8 4 5 Device level ring object clas...

Page 3: ...reference Important note Non compliance may result in malfunction or interference Information Supplementary note 9 2 1 First set up 26 10 Parameter setting 27 11 Operating and display elements 27 11...

Page 4: ...inger contact to IP 20 for qualified personnel is only ensured if the terminals have been completely inserted Therefore the unit must always be mounted in a control cabinet of at least IP 54 which can...

Page 5: ...tion monitoring vibration diagnostics analysis of other dynamic signals Alternatively the dynamic inputs can also be used like an analogue input with an analogue current signal 4 20 mA The hardware ou...

Page 6: ...irmware and operating software download area www ifm com A description of all firmware parameters and their meaning VES004 PC software manual 5 2 Description of functions With the device vibration mon...

Page 7: ...device networking is possible to visualise data measured values alarm states in other systems e g SCADA MES Data e g measured values alarm states limits rotational speeds timer readings is exchanged b...

Page 8: ...t possible contact between shielding and ground Before initial start up the ground or shielding connection of cables must be checked for low resistance continuity 6 2 Cable routing in control cabinets...

Page 9: ...e g acceleration values 7 1 Wiring 18 17 20 19 14 13 16 15 22 21 24 23 6 5 8 7 2 1 4 3 10 9 12 11 Supply L GND OU 1 switch analog OU 2 switch IN 1 0 4 20 mA pulse GND 1 IN 2 0 4 20 mA pulse GND 2 1 2...

Page 10: ...r circuits ungrounded when the sensors are connected so that no dangerous contact voltages are applied to the sensor or transferred to the device If the DC circuit is to be grounded e g due to nationa...

Page 11: ...signal connected to the analogue input IN1 IN2 External inputs input name Real 4 bytes Value of the external input External_xx Objects Time domain object name Value Real 4 bytes Object value in SI uni...

Page 12: ...ex0010 invalid base line Hex0020 invalid reference value 1 Hex0040 invalid reference value 2 Hex0100 deactivated by signal weighting Hex0200 reference value out of range Hex1000 warning alarm Hex2000...

Page 13: ...age alarm Real 4 bytes Limits damage alarm relative Counter counter name DINT 4 bytes Counter value in seconds Alarms alarm name Byte 1 byte Alarm state 0 1 General Variant Byte 1 byte Current variant...

Page 14: ...e Set ID 1 32 of the counter Set counter value DINT 4 bytes Set value of the counter selected with the ID in seconds 8 3 Supported communication types Requirement Parameters Explicit messaging Based o...

Page 15: ...UINT 151 4 Revision Major Revision Minor revision Get STRUCT of USINT USINT e g 1 1 5 Status Get WORD Bit 0 n a Default Value 0 Bit 1 n a Default Value 0 Bit 2 n a Default Value 0 Bit 3 n a Default Va...

Page 16: ...connection Class attributes Attribute Name Access Data type Value 1 Revision Get UINT 2 2 Max instance Get UINT 255 Instance attributes Attribute Name access Data type Value 3 Data Get Array of Byte C...

Page 17: ...op detected 3 Partial Network fault 4 Rapid fault Restore cycle 10 Active supervisor address Get STRUCT of UDINT ARRAY of 6 USINTs IP and or MAC address of the active ring supervisor Supervisor IP add...

Page 18: ...description 4 DSCP urgent Get Set USINT DSCP value for CIP transport class 0 1 Urgent priority message default 55 5 DSCP scheduled Get Set USINT DSCP value for CIP transport class 0 1 Scheduled priori...

Page 19: ...Bit 0 3 Interface configuration Status Bit 4 Mcast pending always 0 Bit 5 Interface configuration pending Bit 6 ACD Status Bit 7 ACD Fault Bit 8 31 Reserved 2 Configuration capability Gett DWORD Bit 0...

Page 20: ...ways empty 6 Host name Get Set STRING Default Domain Name always empty 10 Select ACD Get Set Bool 0 disable 1 enable default 11 Last conflict detected ACD Activity Remote MAC ArpPdu Set STRUCT of USIN...

Page 21: ...e description 1 Interface speed Get UDINT Interface Speed currently in use Speed in bps e g 10 100 2 Interface flags Get DWORD Bit 0 Link Status Bit 1 Half Full Duplex Status 0 Half Duplex 1 Full Dupl...

Page 22: ...the device 2 Twisted pair 3 Optical fiber 4 255 Reserved 8 Interface State Get USINT Current operational state of the interface 0 Unknown interface state 1 The interface is enabled and is ready to sen...

Page 23: ...Input Assembly 255 Bytes_C 0x04 107 0 254 Input Assembly 255 Bytes_D Output process data Object Class Assembly instance no Byte Description 0x04 150 0 9 Output Assembly 16Bytes 0x04 151 0 31 Output As...

Page 24: ...32 byte input 8 Input Only 102 Connection with 64 byte input 9 Input Only 103 Connection with 128 byte input 10 Input Only 104 Connection with 255 byte input 11 Input Only 105 Connection with 255 byt...

Page 25: ...a redundant 1 ring topology by using the DLR protocol 8 7 3 Address Conflict Detection ACD Requirement Parameters Address Conflict Detection ACD yes Description The device supports the recognition of...

Page 26: ...3321 Subnet mask 255 255 255 0 Default gateway 192 168 0 244 MAC address Defined in the product process 9 2 Factory setting VSE151 EtherNet IP Requirement Parameter IP address No IP address assigned...

Page 27: ...ters and possible configurations we refer you to the VES004 software manual The parameter setting of the EtherNet IP device is done via the configuration tool of the EtherNet IP controller Integrate t...

Page 28: ...nately Monitoring not possible faulty parameter set Green red flashing alternately System error EEPROM faulty other states Error in the system device function restricted 11 3 Operating states of the n...

Page 29: ...shing approx 2 Hz Parameter set was successful transferred 11 4 LED test when device is switched on For the network and modus status LED the following switching sequence is to be carried out as LED te...