background image

QHA210

12

w

[Network (ip)] opens.

u

Enter the new IP address using the keyboard and select [Ok].

w

[Network configuration] opens.

Now the settings must also be made for the network mask, gateway and the DNS servers. Once
all settings have been made, they must be permanently saved.

u

Select [S) Save the configuration].

w

The message [The network configuration was successfully changed] is displayed.

u

Confirm the message with [Ok].

u

Select [R) Return to the previous menu] several times to return to the [Main menu].

w

The system is configured and available via web interface.

7.3.3 Set-up completed

u

Select [X) Exit].

w

The [Main menu] is closed.

The following systems are available via the web browser:

appliance management system: Opening the appliance management system (AMS) (

Ò

 

/

 12)

moneo: Opening moneo (

Ò

 

/

 13)

7.4 Opening the appliance management system (AMS)

7.4.1 Requirements

Device (e.g. PC) for connection to the moneo|appliance. This device must be connected to the same
network as the Ethernet interface (ETH 2) of the moneo|appliance.

For access to the appliance management system, a suitable web browser must be installed on the
user’s own PC.

Documentation of the serial number (product label) on the bottom of the housing Requirements

It is recommended to use one of the following browsers:

Google Chrome

Mozilla Firefox

7.4.2 Initial login via the browser

u

Open the URL of the appliance management system in your browser.

https://<IP or hostname>/ams

w

General status information is displayed.

u

Click on the symbol 

.

u

Log in as administrator with the login details assigned in the AMS console.

If the user has not previously logged into the AMS console, use the following login details:

User name: 

administrator

Password: 

<serial number of moneo|appliance>

u

Enter the login details and confirm with [Login].

Summary of Contents for QHA210

Page 1: ...Instructions for set up moneo appliance QHA210 V1 9 or higher 11436162 00 05 2022 GB...

Page 2: ...of the housing 8 6 2 Connecting operating voltage 8 6 3 Wiring 8 7 Set up 10 7 1 Requirements 10 7 2 Preparations 10 7 3 Set up of moneo appliance 10 7 3 1 Adapting the hostname 11 7 3 2 Adapting the...

Page 3: ...ng or at www ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or int...

Page 4: ...e system Read this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions withou...

Page 5: ...QHA210 5 3 Intended use IT hardware to operate moneo incl management system for appliance maintenance...

Page 6: ...e moneo appliance Monitoring and restarting services Importing software updates Displaying contact details for technical support Setting the access for remote support Reading log files Data backup The...

Page 7: ...ce to a DIN rail using the bracket on the back u To remove pull down the retaining latch with a screwdriver The device is rated for convection cooling u Do not impede the air circulation Observe the o...

Page 8: ...is designed to be powered by an approved power supply or DC power source The adapter is designed for 10 36 VDC and 7 7 1 31 A as well as a maximum temperature of 70 C 158 F Before connecting the devic...

Page 9: ...USB 3 0 4 1x USB 2 0 5 Ethernet interface A 6 Ethernet interface B 7 2x display port 8 Voltage supply 9 Ground For special configurations observe the device s operating instructions The device has DI...

Page 10: ...liance can be switched on via the on off switch on the front of the device Make sure that all cables have been connected according to the description 7 3 Set up of moneo appliance The initial set up o...

Page 11: ...f moneo appliance u Note that the entry is case sensitive The host name can be adapted when signing in for the first time or later by following the below steps u Open the Main menu u Select C Configur...

Page 12: ...ning the appliance management system AMS 7 4 1 Requirements Device e g PC for connection to the moneo appliance This device must be connected to the same network as the Ethernet interface ETH 2 of the...

Page 13: ...functional scope is displayed Password requirements At least 8 characters Must contain at least one upper case letter at least one lower case letter at least one number at least one special character...

Reviews: