![IFM OY4**S Series Operating Instructions Manual Download Page 28](http://html1.mh-extra.com/html/ifm/oy4-s-series/oy4-s-series_operating-instructions-manual_4114129028.webp)
28
10.2 Functional test of the safety light curtains
Check the proper function of the safety light curtains before work starts.
For the functional test a test object in accordance with a resolution of the safety
light curtains has to be used.
For information about available test rods see:
www.ifm.com
→ Products → Accessories.
►
Let the test object enter the protected area and move it slightly downwards.
First of all in the centre and then close to the transmitter and the receiver.
►
Make sure that the red LED on the receiver is continuously lit during the
movement in the protected area.
Observe the notes on installation of the safety light curtains → 14
Maintenance, repair and disposal.
Notes on setup → 17.1 Check list.