![IFM LW2720 Operating Instructions Manual Download Page 24](http://html1.mh-extra.com/html/ifm/lw2720/lw2720_operating-instructions-manual_3929236024.webp)
LW2720
Electronic level sensor
24
2
1
u
Remove the O-ring (1) from the unit before mounting.
Otherwise, the O-ring may come off due to the missing end stop and
enter the process. In this case, the seal is formed by the rear flat seal
(2) (non-hygienic).
39 mm
u
Make sure that the rear flat seal (profiled sealing ring) is on the unit.
u
Screw the unit into the adapter.
u
Recommended tightening torque: 35 Nm.