![background image](http://html.mh-extra.com/html/ifm/efector400/efector400_brief-instructions_620714013.webp)
706414/00
Page 13 of 14
© ifm efector gmbh
5.2 Reset:
Operand AD 100 (for set E address 100...103), display format HEX, enter 8 at the
first position in the control value (DW = Double Word) for a value change.
Only a change of the status value from 0 to 8 is detected; no value change is carried
out when the status value of 8 remains 8.
(
Attention! Only to be carried out when the encoder is standing still
)
Example reset:
OPERAND
DISPLAY FORMAT
STATUS VALUE
CONTROL
VALUE
ED 100
Dec..
L#5120
AD 100
Hex.:
DW#
0
000 0000
8000 0000
OPERAND
DISPLAY FORMAT
STATUS VALUE
CONTROL
VALUE
ED 100
Dec..
L#0
AD 100
Hex.:
DW#
8
000 0000
8000 0000
5.3 Preset:
Operand AD 100 (for set E address 100...103), display format HEX, enter 8 at the
first position in the control value (DW = Double Word) for a value change.
Only a change of the status value from 0 to 8 is detected; no value change is carried
out when the status value of 8 remains 8.
(
Attention! Only to be carried out when the encoder is standing still
)
Example Preset:
OPERAND
DISPLAY FORMAT
STATUS VALUE
CONTROL
VALUE
ED 100
Dec..
L#0
AD 100
Hex.:
DW#
0
000 0000
8000 0E10
OPERAND
DISPLAY FORMAT
STATUS VALUE
CONTROL
VALUE
ED 100
Dec..
L#3600
AD 100
Hex.:
DW#
8
000 0E10
8000 0E10
3600 (decimal) = 0E10 (hex)