3.2
Setting examples with high and low word
For some controllers the value for the total measuring range must be converted to a high
word and a low word.
Standard setting 8192 units x 4096 revolutions:
8192
units x 4096 revolutions
=> total measuring range 33 554 432
total measuring range 33 554 432 in hex => 0200 0000 hex
high word 0200 hex in decimal
=>
512
low word 0000 hex in decimal
=>
0
200 units x 24 revolutions - enable scaling:
200
units x 24 revolutions
=> total measuring range 4800
total measuring range 4800 in hex => 0000 12C0 hex
high word 0000 hex in decimal
=>
0
low word 12C0 hex in decimal
=>
4800
200 units x 1 revolution - enable scaling:
200
units x 1 revolution
=> total measuring range 200
total measuring range 200 in hex
=> 0000 00C8 hex
high word 0000 hex in decimal
=>
0
low
word
00C8
hex
in
decimal
=>
200