Wiring is also indicated on the housing cap. If there is a deviation, the
encoder must be connected as indicated on the label on the housing
cap.
The wires L+ (sensor) and 0V (sensor) are internally connected to the
supply voltage. When using external electronics which regulate the
supply voltage these wires can be used as test wires. If unused, these
wires must be connected to the supply voltage or insulated.
Depending on the version, the electrical connection is made via the
cable or via cables to be obtained separately.
When using suitable cables the maximum cable length is 100 m for the
5 V TTL version and 300 m for the 10...30 V HTL version.
7
ifm1013.xx
5-wire cable 13-wire cable
L+
1
brown
brown/green
L+ sensor
-
-
blue
0V
6
grey
white/green
0V sensor
-
-
white
A
2
green
brown
A neg.
-
-
green
B
4
white
grey
B neg.
-
-
pink
0 index
5
yellow
red
0 index neg.
-
-
black
fault neg.
-
-
lilac
free
-
-
-
free
-
-
yellow
screen
3
housing
housing