Function and features
The encoder transforms rotational movement into pulse sequences.
These allow the measurement of linear distances and angular move-
ment as well as the determination of positions.
Electrical connection
Disconnect power from the installation before connecting or dis-
connecting cables or connectors!
Unused wires must be insulated to avoid short circuits and cross
faults.
Short-circuit protection
5 V TTL version:
outputs short-circuit protected against 0 V
10...30 V HTL version:
outputs short-circuit protected against 0 V
and L+ for maximum 1 minute
Standard wiring:
6
Flange plug
ifm1000.xx
ifm1001.xx
5-pole
L+
2
9
12
L+ sensor
-
5
2
0V
1
12
10
0V sensor
-
10
11
A
3
1
5
A neg.
-
2
6
B
4
3
8
B neg.
-
4
1
0 index
5
6
3
0 index neg.
-
7
4
fault neg.
-
-
7
free
-
-
9
free
-
-
-
screen
housing
11
housing