background image

4.2 PDM360

The Ethernet service interface behind the side cover is not intended for
actual operation.

ETHERNET CAMERA

O2M110

9

UK

RJ45

Pin

Potential

1

TxD +

pair 1

2

TxD –

3

RxD +

pair 2

6

RxD –

1

8

12

11

10

9

8

7

6

5

4

3

2

1

18

19

15

17

13

16

14

M23 round connector

Pin

Potential

1

GND (Power)

2

GND (Power)

3

VBB + (Supply)

4

CAN 1 Low 

5

CAN 1 High 

6

n.c.

7

2nd RS 232, RxD

8

2nd RS 232, TxD

9

VBB + (supply switched)

10

GND (Power)

11

GND (Power)

12

n.c.

13

CAN 2 Low 

14

CAN 2 High

15

Ethernet RxD –

16

Ethernet RxD +

17

Ethernet TxD –

18

Ethernet TxD +

19

Shield

Operating connection

M23 round connector

(19-pole central plug)

Ethernet service interface

(8-pole RJ45 plug)

A

B

A

B

PDM360 rear view and side view

PDM360 operating connection

PDM360 service connection

Summary of Contents for Efector 250 O2M110

Page 1: ...Device manual Ethernet camera for mobile applications O2M110 UK 7390715 00 03 2012 ...

Page 2: ... PDM360 page 11 One camera at one PC notebook service mode page 11 4 5 Connection principle with hub switch Several cameras at one PDM360 page 12 5 Operating and display elements page 13 6 Set up 6 1 IP addresses page 14 6 1 1 IP address allocation PDM360 page 14 6 1 2 IP address allocation cameras page 15 6 2 Parameter setting PDM360 page 19 6 2 1 Library ifm_Camera_O2M_Vxxxxxx page 19 6 2 2 Func...

Page 3: ...es Open source software This unit contains maybe modified Open Source software which is subject to special licensing terms For copyright information and licensing terms please refer to www ifm com int GNU For software subject to the GNU General Public License or the GNU Lesser General Public License the source code can be requested against payment of the copying and shipping costs ETHERNET CAMERA ...

Page 4: ...to the criteria for safety extra low voltage SELV as this voltage is supplied without further measures to the connected controller the sensors and the actuators The wiring of all signals in connection with the SELV circuit of the device must also comply with the SELV criteria safety extra low voltage safe electrical separation from other electric circuits If the supplied SELV voltage has an extern...

Page 5: ... PDM360 version with colour display art no CR1051 from software version V4 3 2 Display of up to 4 camera images per PDM360 10 Mbits s Ethernet interface 10Base T 100Base TX according to IEEE 802 3 802 3u Sealed diecast zinc housing Protection rating IP 69 K Regulated lens heating can be deactivated CMOS image sensor resolution VGA 320 x 240 pixels Angle of aperture 75 Parameter setting and control...

Page 6: ...he camera 7 Technical data data sheets www ifm electronic com www ifm electronic com ETHERNET CAMERA O2M110 6 Mounting accessories examples Art no Mounting set for shaft Ø 12 mm E2D110 clamp cylinder and fixing element for the types O2D O2M Shaft straight Ø 12 mm length 130 mm M10 E20938 Shaft angled Ø 12 mm length 200 mm M10 E20940 Mounting set for shaft Ø 14 mm E2D112 clamp cylinder and fixing e...

Page 7: ...on etc Avoid back light Do not position lighting elements directly facing the camera lens Mount the device in such a way that the cables connectors are connected from below The connected cables must be provided with a strain relief ETHERNET CAMERA O2M110 7 UK Arbeitsabstand m Bildfeldbreite m 1 2 3 4 5 0 1 5 3 0 7 5 4 5 6 0 Ethernet Kamera x 1 1 x 2 2 x 5 5 x 3 3 x 4 4 Bildfeldhöhe m width of fiel...

Page 8: ...ot lay the Ethernet connection cable in parallel to current carrying cables Lay supply and signal cables away from the camera using the shortest possible route 4 1 2 Interference due to external influences Faulty or insufficient radio interference suppressors in electrical equipment such as inverters or generators as well as voltage fluctuations when switching on off electric loads may lead to pro...

Page 9: ...Potential 1 GND Power 2 GND Power 3 VBB Supply 4 CAN 1 Low 5 CAN 1 High 6 n c 7 2nd RS232 RxD 8 2nd RS232 TxD 9 VBB supply switched 10 GND Power 11 GND Power 12 n c 13 CAN 2 Low 14 CAN 2 High 15 Ethernet RxD 16 Ethernet RxD 17 Ethernet TxD 18 Ethernet TxD 19 Shield Operating connection M23 round connector 19 pole central plug Ethernet service interface 8 pole RJ45 plug A B A B PDM360 rear view and...

Page 10: ...nterface B of the PDM360 Note The IP address range Net ID of the PC must correspond to the IP address range of the camera For the PC notebook setting is carried out in the Control Panel Network Connections Properties also see 6 1 2 IP address allocation Ethernet cameras ETHERNET CAMERA O2M110 10 RJ45 Pin Potential 1 TxD pair 1 2 TxD 3 RxD pair 2 6 RxD 1 8 Ethernet interface 8 pole RJ45 plug PC not...

Page 11: ...k cable Ethernet Camera PC Notebook Crosslink cable example art no Ethernet connection cable 2m M12 connector 4 pole D coded RJ45 8 pole E11898 Operating connection M23 round connector 19 pole Service connection RJ45 plug 8 pole Connection RJ45 plug 8 pole Ethernet interface Definition crosslink crosslink cable crossover cable for the direct connection of network participants Connection principle ...

Page 12: ...are automatically recognised by these devices In this case 1 1 patch cables are not compulsory ETHERNET CAMERA O2M110 12 patch cable 1 1 Display Ethernet Cameras patch cables 1 1 Hub Switch Definition patch cable patch cable uncrossed cable 1 1 wiring straight through cable point to point i Connection principle with hub switch TxD TxD RxD RxD TxD TxD RxD RxD patch cable 1 1 Patch cable principle 1...

Page 13: ...5 Operation display ETHERNET CAMERA O2M110 13 UK LED green LED Description ON supply voltage ok camera ready for operation OFF no supply voltage power supply interrupted Operating indication O2M110 111 ...

Page 14: ...allocation PDM360 For PDM360 the IP address is set via the PDM setup Open the PDM setup start menu Press F1 and F5 simultaneously and switch on the voltage supply Select IP address by turning and then pressing the rotary switch Set the IP address range in the menu Setup Server IP ETHERNET CAMERA O2M110 14 Ethernet Camera Display Hub Switch PC Notebook Example 1 IP address allocation 192 168 82 247...

Page 15: ...otocol TCP IP IP address 192 168 82 xx except 15 Subnet mask 255 255 255 0 Connection 10 MBits half duplex Gateway IP address 192 168 82 15 2 Establish an Ethernet connection between the camera and the PC notebook 3 Connect the camera to supply voltage Do not interrupt the supply voltage during IP address allocation Avoid voltage fluctuations during IP address allocation 4 Open the internet browse...

Page 16: ...6 Click on Change IP address 7 Enter the new address in the field IP address and click on Submit to send it to the camera ETHERNET CAMERA O2M110 16 Start window O2M1xx WebConfig O2M1xx IP configuration ...

Page 17: ...n appears if the address was successfully written to the flash memory of the camera ETHERNET CAMERA O2M110 17 UK Confirmation of the address change Error message in case of invalid IP address e g wrong address range ...

Page 18: ...address line of the browser and confirm with Enter here e g http 192 168 82 17 If the address corresponds to the previously allocated address the start window O2M1xxx WebConfig appears again 10 Repeat the steps 2 to 9 with further cameras The new camera IP address will become effective on reboot camera supply voltage off on ETHERNET CAMERA O2M110 18 O2M1xx IP configuration reboot request to check ...

Page 19: ...V2 3 Targets ifm Library ifm_CR1051 The library uses functions of the library ifm_Camera_Vxxxxxx It is loaded automatically ifm_Camera_Vxxxxxx must not be inserted 2 demo programs in the directory Projects DEMO_PDM serve for introduction CR1051Demo_O2M_1CAM pro und CR1051Demo_O2M_2CAM pro 6 2 2 Function CAM_O2M The function is part of the above mentioned library It serves for parameter setting con...

Page 20: ...en at the top left no PDM360 visualisation 31 screen at the top left PDM360 visualisation at the bottom height 120 px 40 screen at the top right no PDM360 visualisation 41 screen at the top right PDM360 visualisation at the bottom height 120 px 50 screen at the bottom left no PDM360 visualisation 51 screen at the bottom left PDM360 visualisation at the top height 120 px 60 screen at the bottom rig...

Page 21: ...en 2 function being processed 3 error connection disturbed or interrupted parameter not written reinitialise function 97 check last byte of IP dress last byte of the IP adress between camera and PDM has to be different 98 PDM IP adress and camera IP adress are not in the same group 99 wrong IP adress check format of the input string PDM_IP STRING 15 IP address of the connected PDM360 ...

Page 22: ...d screen at the bottom left 1 camera active visualisation 120 px at the top C_MODE 51 C_WINDOW_HEIGHT not defined screen at the bottom right 1 camera active visualisation 120 px at the top C_MODE 61 C_WINDOW_HEIGHT not defined screen at the top left top right 2 cameras active visualisation 120 px at the bottom controlled by camera 1 Camera 1 C_MODE 31 Camera 2 C_MODE 40 C_WINDOW_HEIGHT not defined...

Page 23: ...ft Camera 3 C_MODE 60 at the bottom right C_WINDOW_HEIGHT not defined all cameras screen at the top left top right bottom left bottom right 4 cameras active no visualisation Camera 1 C_MODE 30 at the top left Camera 2 C_MODE 40 at the top right Camera 3 C_MODE 50 at the bottom left Camera 4 C_MODE 60 at the bottom right C_WINDOW_HEIGHT not defined all cameras Legend Camera image Active PDM360 visu...

Page 24: ...ew size m Operating voltage V Power consumption W Lens heating W Type of sensor Image repetition rate Hz Protocol Data format Readiness for operation LED Operating temperature C Storage temperature C Protection Standards tests Materials Interface Transmission rate IP address default Wiring 55 45 45 6 21 1 34 1 4 3 42 57 80 M12x1 M12x1 60 20 5 24 5 30 5 1 O2M110 Ethernet camera Angle of aperture 75...

Page 25: ...using as the device does not contain any components which must be maintained by the user The unit may only be repaired by the manufacturer Dispose of the device in accordance with the national environmental regulations 9 Approvals standards Test standards and provisions 7 Technical data The CE Declaration of Conformity and the e1 approval are available at Data sheet direct e g O2M110 Approvals www...

Reviews: