![IFM Efector 250 O2M110 Device Manual Download Page 8](http://html.mh-extra.com/html/ifm/efector-250-o2m110/efector-250-o2m110_device-manual_620673008.webp)
4 Electrical connection
4.1 Ethernet camera
For information about available connectors please go to:
➔
Data sheet direct
➔
e.g. O2M110
➔
Accessories
The supply voltage is electrically separated from the housing.
4.1.1 Ethernet connection
Use a shielded CAT5 cable.
(STP, Shielded Twisted Pair, according to EIA/TIA-568). Max. length 100 m
Use screened connector housings.
Connect the screen of the Ethernet cable to the connector housing.
Avoid transmission problems caused by induction.
Do not lay the Ethernet connection cable in parallel to current-carrying cables.
Lay supply and signal cables away from the camera using the shortest possible
route.
4.1.2 Interference due to external influences
Faulty or insufficient radio interference suppressors in electrical equipment, such
as inverters or generators, as well as voltage fluctuations when switching on/off
electric loads may lead to problems with the image transmission.
www.ifm-electronic.com
ETHERNET CAMERA
O2M110
8
4
2
1
3
1
2
3
4
Supply voltage
Pin
Potential
1
8...32 V DC
2
n.c.
3
0 V
4
n.c.
Ethernet
Pin
Potential
1
TxD +
2
RxD +
3
TxD –
4
RxD –
M12 supply connection
(4-pole, A-coded)
M12 Ethernet
(4-pole, D-coded)
Wiring