background image

4

If the setting of the sensitivity is not possible (e.g. object signal and 
background signal are about the same), the red LED flashes after step 
3 for approx. 2s. The unit then passes into the operating mode with the 
sensitivity being unchanged.

Setting of the maximum sensitivity

Go into the programming mode (step 1).
Align the unit so that no light is reflected.
Press the setting button twice (see steps 2 and 3).

Locking / Unlocking

Press for 10s

The red LED lights for a short time, 
then the yellow and green LEDs flash 
alternately;
after 10s the LEDs go out, the unit is 
locked.

Press for 10s

After 10s the LEDs go out, locking is 
cancelled.

Operation

Check the safe functioning of the diffuse reflection sensor. Display by LEDs.

LED green lights

Unit is ready for operation.

LED yellow lights

Output is switched.

LEDs red

Flash alternately, 2 Hz: output short-circuited.
Flash alternately, 1 Hz: internal malfunction,
(output is not switched).

Maintenance

Keep the lens of the sensor free from soiling.
For cleaning do not use any solvents or cleaning agents which could damage the 
plastic lenses.