background image

3

UK

Setting of the sensitivity with stationary objects

1

Activate the programming mode of the unit without object.

Press for about 2s until the red LED flashes.

The red LED goes out; the yellow and green LEDs flash alternately.
The unit is in the programming mode.
If in addition the red LED is lit, the reflection of the background is too intensive (e.g. 
reflecting surface). Angle the unit in the horizontal plane until the red LED goes out.
If you continue with step 3 although the red LED is lit, programming is interrupted. 
The unit then passes into the operating mode with the setting being unchanged.

2

Setting without object.

Press once.

The yellow and green LEDs go out for approx. 1s, then flash again alternately.

3

Setting with object.

Press once.

The yellow and green LEDs go out for approx. 1s, then the green LED is on.
The unit is in the operating mode.

Programming is only possible if you keep to this order (first background, then 
object).