34
Scale drawing
12
30
63
M
12
x1
G
4
3
8
6
32
I1
L
50
57
A
I2
3
2
1
78
87
Dimensions in mm
1: display; 2: status LEDs; 3: programming buttons; 4: seal
cm
inch
min
max
min
max
L (probe length)
10
160
4�0
63
A (active zone)
6 (4)
L - 4 (L - 6)
2�4 (1�6)
L - 1�6 (L - 2�4)
I1 (inactive zone 1)
3
1�2
I2 (inactive zone 2)
1 (3)
0�4 (1�2)
The values in brackets apply to the setting [MEdI] = [LOW] (setting for the detection of oils
and oil-based media)�