background image

Operating instructions

Process and dialogue module

ecomatDisplay

CR1202

11427078 / 00   03 / 2022

GB

Summary of Contents for ecomatDisplay CR1202

Page 1: ...Operating instructions Process and dialogue module ecomatDisplay CR1202 11427078 00 03 2022 GB ...

Page 2: ...ace mounting with RAM mount system 11 4 4 1 Mounting steps 12 4 5 Other installation types 12 5 Electrical connection 13 5 1 Wiring 13 5 2 Connection accessories 13 5 3 Connection technology 13 5 4 General wiring information 14 5 5 Operating voltage and circuit breakers 15 5 6 Shield connection 16 5 7 Ethernet interface 16 5 8 Analogue video inputs 17 5 9 USB interfaces 17 5 9 1 Short circuit prot...

Page 3: ...Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTENTION Warning of damage to property CAUTION Warning of personal injury w Slight reversible injuries may result WARNING Warning of serious personal injury w Death or serious irreversible injuries may r...

Page 4: ...uring the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose Ò Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequenc...

Page 5: ...interfaces Together with the Linux operating system they form a universal platform for networking and communication with other CAN devices networks or PCs By default the device is not intended for direct connection to IT structures If this application is required the users have to implement it e g by using their own additional components This is a class A product This product may cause radio inter...

Page 6: ... with button Ethernet interfaces 1 CAN interfaces 4 ifm plug play CAN based 1 USB 2 0 interfaces 1 Analogue video inputs 2 Digital inputs BL 2 Digital outputs 2 5 A 2 Line In Speaker output 1 Headphone output Controller Dual Core with GPU 800 MHz RAM 1 GB FLASH 4 GB available not available ...

Page 7: ... in the application with regard to shock vibration acceleration and weight lies with the system architect ATTENTION Impact stress on display screen w Damage possible w Protection rating and electrical protection might be impaired w Risk of injury possible u If necessary the system creator must take external measures to protect the device depending on the requirements of the corresponding applicati...

Page 8: ...ion ducts with elastic materials may damage the device u Do not use any sealing materials in the area around the pressure compensation elements 4 2 2 Light sensor and status LED The device is equipped with a light sensor It is used to adapt the brightness of the display and the operating elements automatically to the ambient brightness conditions 2 1 1 Light sensor 2 Status LED u Avoid constructio...

Page 9: ...e system creator When installing the device in a control cabinet the following requirements concerning fire protection apply If installed according to the information given in 4 3 the device itself complies with the requirements of the IEC or DIN EN 61010 2 201 for a closed device to prevent fire from spreading WARNING The damping strip installation kit has no flammability rating and thus presents...

Page 10: ...les of the installation kit Fig 3 Dialogue module with mounted installation kit Only insert the fixing profiles from the installation kit in combination with the damping strip 4 3 3 Panel cutout u Make a cut out 149 5 328 4 x R5 Fig 4 Panel cut out Tolerances 0 5 mm 4 3 4 Mounting steps u Screw the set screws into the M5 thread on the back of the device Location for mounting accessories Ò 7 u Atta...

Page 11: ...ened set screws A Fig 7 Dimensions Installation depth A device depth approx 54 mm Installation depth with the attached connector ap prox 78 mm The fixing profiles and set screws from the installation kit do not protrude from the device 4 4 Surface mounting with RAM mount system Using the RAM mount components available as accessories the dialogue unit can be used as a firmly mounted desktop unit Tw...

Page 12: ... 5 56 62 6 Fig 10 Mounting plate with ball head 38 1 30 5 3 Fig 11 Hole dimensions Tightening torque 5 0 5 Nm u Slightly loosen the fastening screw of the mounting arm u Place the mounting arm onto the ball heads and tighten the fastening screw 4 5 Other installation types Permissible installation types Panel mounting control cabinet installation Ò 9 Surface mounting with RAM mount system Ò 11 All...

Page 13: ...TION Reverse polarity protection not ensured in case of power supply SELV PELV on VBB30 and VBB0 Reverse polarity protection is only ensured in case of supply via the on board system via a battery if the polarity of the supply is reversed as a whole battery connected incorrectly The basic principle of the reverse polarity protection is that the upstream fuses are quickly switched off in case of ex...

Page 14: ...USB type A connector of the connected M12 adapter The ingress resistance of cables that users have cut to length must be guaranteed u Use twisted pair cables for the CAN IFM connection The CAN bus is internally protected against short circuit to VBB and GND For CAN IFM cables 30 m ensure appropriate protection against surge e g shielded cables u For the Ethernet connection use a minimum category 5...

Page 15: ...le and visible distortion 5 5 Operating voltage and circuit breakers u The individual electric circuits must be protected in order to protect the whole system Automotive spade type fuses are recommended Designation Connector 1 Operating voltage Nominal value fuse Required triggering characteristics VBB15 Pin 119 8 16 V DC and 16 32 V DC Ignition starter switch 3 A Tfuse 120 s at max 6 25 A VBB30 P...

Page 16: ... on a zinc nickel basis with thick film passivation and sealing 5 7 Ethernet interface Communication interfaces are insulated from each other from other circuits and from touchable device surfaces with basic insulation according to IEC62368 1 as an external circuit u Use a screened CAT5 cable STP Shielded Twisted Pair to EIA TIA 568 Length max 30 m The max cable length depends for example on the b...

Page 17: ...nnector B coded on USB socket type A watertight cable length 1 5 m wires twisted and screened u If self assembling cables please only use cables according to USB 2 0 specification Keep length B as short as possible and position the USB connector in the immediate vicinity of the dialogue module The length B considerably influences the quality of the USB data transmission B Connection USB connector ...

Page 18: ...CR1202 18 5 10 Selection of loudspeakers For optimum audio output use 8 Ω loudspeakers ...

Page 19: ... the dialogue module w Shortly after the unit is switched on the start image appears for approx 10 to 15 seconds During this time the booting process is running in the background After booting the App Launcher opens automatically 6 3 Set up The set up allows setting the device parameters directly via the local display or the web interface of the device Select the set up button in the App Launcher ...

Page 20: ...ice temperature must not exceed the maximum permissible value Technical data www ifm com The value provided by the internal temperature sensor can e g be used for the following actions Reduction of the display brightness to decrease internal heating Warning the operator about the heating indicating an upcoming switch off of the display Switch off of the display ATTENTION Internal temperature excee...

Page 21: ...acts inside w Damage to the device possible u Clean the area around the service cover before opening it u Remove the service cover on the back of the device width across flats 13 mm or u Protect inside of device sealing areas and sealing of the service cover from soiling and humidity u When changing the battery take ESD precautions u Remove the battery and replace it with a new one Observe the pol...

Page 22: ... of severe soiling use a damp cloth Micro fibre cloths without chemical additives are recommended 7 3 Cleaning the housing surface u Disconnect the device u Clean the device from dirt using a soft chemically untreated and dry cloth u In case of severe soiling use a damp cloth 7 4 Repair u The device must only be repaired by the manufacturer Observe the safety instructions Ò Safety instructions 7 5...

Reviews: