background image

Operating instructions

Process and dialogue module

ecomatDisplay

CR1077

11433915 / 00   03 / 2022

GB

Summary of Contents for ecomatDisplay CR1077

Page 1: ...Operating instructions Process and dialogue module ecomatDisplay CR1077 11433915 00 03 2022 GB ...

Page 2: ...ace mounting with RAM mount system 12 4 4 1 Mounting steps 12 4 5 Other installation types 13 5 Electrical connection 14 5 1 Wiring 14 5 2 Connection accessories 14 5 3 Connection technology 14 5 4 General wiring information 15 5 5 Operating voltage and circuit breakers 17 5 6 Shield connection 17 5 7 Ethernet interface 18 5 8 Analogue video inputs 18 5 9 USB interfaces 18 5 9 1 Short circuit prot...

Page 3: ...Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTENTION Warning of damage to property CAUTION Warning of personal injury w Slight reversible injuries may result WARNING Warning of serious personal injury w Death or serious irreversible injuries may r...

Page 4: ...uring the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose Ò Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequenc...

Page 5: ... interfaces Together with the Linux operating system they form a universal platform for networking and communication with other CAN devices networks or PCs By default the device is not intended for direct connection to IT structures If this application is required the users have to implement it e g by using their own additional components This is a class A product This product may cause radio inte...

Page 6: ...ith button 1 Ethernet interfaces 2 CAN interfaces 4 ifm plug play CAN based 2 USB 2 0 interfaces 2 Analogue video inputs 4 Digital inputs BL 2 Digital outputs 2 5 A 2 Line In 1 Speaker output 1 Headphone output 1 Controller Quad core with GPU 1 2 GHz RAM 1 GB FLASH 8 GB available not available ...

Page 7: ... in the application with regard to shock vibration acceleration and weight lies with the system architect ATTENTION Impact stress on display screen w Damage possible w Protection rating and electrical protection might be impaired w Risk of injury possible u If necessary the system creator must take external measures to protect the device depending on the requirements of the corresponding applicati...

Page 8: ...tic materials may damage the device u Do not use any sealing materials in the area around the pressure compensation elements 4 2 2 Light sensor and status LED The device is equipped with a light sensor It is used to adapt the brightness of the display and the operating elements automatically to the ambient brightness conditions 2 1 1 light sensor 2 status LED u Avoid construction measures that cov...

Page 9: ...e system creator When installing the device in a control cabinet the following requirements concerning fire protection apply If installed according to the information given in 4 3 the device itself complies with the requirements of the IEC or DIN EN 61010 2 201 for a closed device to prevent fire from spreading WARNING The damping strip installation kit has no flammability rating and thus presents...

Page 10: ...cers M5 hexagon nuts washers M5 set screws and damping strips required for mounting are supplied with the installation kit Fig 2 Fixing profile of the installation kit Fig 3 Dialogue module with mounted installation kit Use the fixing profile of the mounting kit only together with a suitable spacer and the damping strip 4 3 3 Panel cutout u Make a cut out 128 213 4 x R7 Fig 4 Panel cut out Toleran...

Page 11: ...w the fixing profile to the back of the device Tightening torque of the M5 hexagon nuts 5 0 5 Nm ATTENTION Contact corrosion between the mounting screws and the housing w Damage to the device u Do not use copper or nickel plated materials for the bolting elements u Use zinc plated screws u In very corrosive environments such as extremely salty air use screws with surface finishing on a zinc nickel...

Page 12: ...the dialogue unit can be used as a firmly mounted desktop unit Two ball heads allow variable orientation of the unit Fig 8 RAM mount components 1 mounting arm with fastening screw 2 mounting plate with ball head Fig 9 Dialogue module with mounted RAM mount system You will find more information about the available RAM mount components at www ifm com 4 4 1 Mounting steps u Screw the mounting plate t...

Page 13: ... fastening screw of the mounting arm u Place the mounting arm onto the ball heads and tighten the fastening screw 4 5 Other installation types Permissible installation types Panel mounting control cabinet installation Ò 9 Surface mounting with RAM mount system Ò 12 All other installation types are in the sole responsibility of the system creator ...

Page 14: ...TION Reverse polarity protection not ensured in case of power supply SELV PELV on VBB30 and VBB0 Reverse polarity protection is only ensured in case of supply via the on board system via a battery if the polarity of the supply is reversed as a whole battery connected incorrectly The basic principle of the reverse polarity protection is that the upstream fuses are quickly switched off in case of ex...

Page 15: ... USB type A connector of the connected M12 adapter The ingress resistance of cables that users have cut to length must be guaranteed u Use twisted pair cables for the CAN IFM connection The CAN bus is internally protected against short circuit to VBB and GND For CAN IFM cables 30 m ensure appropriate protection against surge e g shielded cables u For the Ethernet connection use a minimum category ...

Page 16: ...nnections A short circuit between operating voltage VBB X and USB audio video might cause damage to the device u Lay supply and signal cables away from the device using the shortest possible route u Provide all outgoing cables with a strain relief 200 mm behind the cable entry Maximum cable lengths USB 1 8 m Ethernet 30 m Video 30 m Audio 30 m Minimum operating quality audio video There might be i...

Page 17: ...NTION Load dump and surge without connection of VBB0 w Destruction of the device possible u Always connect VBB0 even if the outputs are not used or are not available 5 6 Shield connection To ensure the protection of the device against electrical interference and to ensure the safe function of the device the housing has to be connected to the body GND of the supply using the shortest possible route...

Page 18: ...generators as well as voltage fluctuations when switching on off electric loads may lead to problems with the data transmission 5 8 Analogue video inputs u If the analogue video inputs are used use connection cables in STP shielded twisted pair or coaxial cables versions with 75 ohms impedance 5 9 USB interfaces Wiring Technical data www ifm com This USB interface is connected to a USB connector i...

Page 19: ... High Speed USB connection cable with twisted and screened cores according to USB 2 0 specification u Do not use more than one USB cable for the connection 5 9 1 Short circuit protection ATTENTION The USB interface M12 connector is not protected against short circuits with a live wire outside the following voltage ranges 5 V DC 0 3 6 0 V DC pin 1 Data 0 3 3 6 V DC pin 2 Data 0 3 3 6 V DC pin 3 ID ...

Page 20: ... Switch on the operating voltage of the dialogue module w Shortly after the unit is switched on the start image appears for approx 10 to 15 seconds During this time the booting process is running in the background After booting the App Launcher opens automatically 6 3 Set up The set up allows setting the device parameters directly via the local display or the web interface of the device Select the...

Page 21: ...ice temperature must not exceed the maximum permissible value Technical data www ifm com The value provided by the internal temperature sensor can e g be used for the following actions Reduction of the display brightness to decrease internal heating Warning the operator about the heating indicating an upcoming switch off of the display Switch off of the display ATTENTION Internal temperature excee...

Page 22: ...acts inside w Damage to the device possible u Clean the area around the service cover before opening it u Remove the service cover on the back of the device width across flats 13 mm or u Protect inside of device sealing areas and sealing of the service cover from soiling and humidity u When changing the battery take ESD precautions u Remove the battery and replace it with a new one Observe the pol...

Page 23: ... of severe soiling use a damp cloth Micro fibre cloths without chemical additives are recommended 7 3 Cleaning the housing surface u Disconnect the device u Clean the device from dirt using a soft chemically untreated and dry cloth u In case of severe soiling use a damp cloth 7 4 Repair u The device must only be repaired by the manufacturer Observe the safety instructions Ò Safety instructions 7 5...

Reviews: