17
ifm
Programming Manual
ecomatmobile
CabinetController (CR0301) Runtime System V05
2016-04-21
System description
Hardware description
>
3.2.3
Inputs (technology)
Analogue inputs ................................................................................................................................... 17
Binary inputs ........................................................................................................................................ 18
Input group ANALOG0...7 ................................................................................................................... 19
Input group IN00...IN07 ....................................................................................................................... 19
Input group IN08...IN11 / FRQ00...FRQ03 .......................................................................................... 19
Input group IN12...IN15 ....................................................................................................................... 20
14090
>
Analogue inputs
2426
The analogue inputs can be configured via the application program. The measuring range can be set
as follows:
• current input 0...20 mA
• voltage input 0...10 V
• voltage input 0...32 V
The voltage measurement can also be carried out ratiometrically (0...1000 ‰, adjustable via function
blocks). This means potentiometers or joysticks can be evaluated without additional reference voltage.
A fluctuation of the supply voltage has no influence on this measured value.
As an alternative, an analogue channel can also be evaluated binarily.
In case of ratiometric measurement the connected sensors should be supplied with VBBs of the
device. So, faulty measurements caused by offset voltage are avoided.
8971
In = pin multifunction input n
(CR) = device
(1) = input filter
(2) = analogue current measuring
(3a) = binary-input plus switching
(3b) = binary-input minus switching
(4a) = analogue voltage measuring 0...10 V
(4b) = analogue voltage measuring 0...32 V
(5) = voltage
(6) = reference voltage
Figure: principle block diagram multifunction input