20
ifm
Programming Manual
ecomatmobile
CabinetController (CR0301) Runtime System V05
2016-04-21
System description
Hardware description
>
Input group IN12...IN15
20858
These inputs are a group of multifunction channels.
These inputs can be used as follows (each input separately configurable):
• binary input plus switching (BL) for positive sensor signal
• binary input minus switching (BH) for negative sensor signal
→ chapter
Possible operating modes inputs/outputs
(
Sensors with diagnostic capabilities to NAMUR can be evaluated.
All inputs show the same behaviour concerning function and diagnosis.
Detailed description
→ chapter
Address assignment inputs / outputs
► Configuration of each input is made via the application program:
• inputs IN12+IN13 via configuration byte IN12_13_MODE
• inputs IN14+IN15 via configuration byte IN14_15_MODE