ENGLISH
INCLINATION SENSOR
EC2082
PAGE
9
Characteristic of the output function
Maintenance, repair and disposal
As the inclination sensor does not contain any components which must be main-
tained by the user, the housing must not be opened. The sensor may only be
maintained by the manufacturer. The disposal must be carried out according to
the corresponding national environmental regulations.
Declaration of conformity
The CE marking is applied on the basis of the EMC directive EMC 2004/108/EEC,
implemented in the standards EN 61000-6-2: 2005 and EN 61000-6-4: 2007.
0,00
1,00
2,00
3,00
4,00
5,00
6,00
7,00
8,00
9,00
10,00
11,00
12,00
13,00
14,00
15,00
16,00
17,00
18,00
19,00
20,00
-90
-80
-70
-60
-50
-40
-30
-20
-10
0
10
20
30
40
50
60
70
80
90
α
[°] I [mA]
-90
4,00
-85
4,02
-80
4,12
-75
4,27
-70
4,48
-65
4,75
-60
5,07
-55
5,45
-50
5,87
-45
6,34
-40
6,86
-35
7,41
-30
8,00
-25
8,62
-20
9,26
-15
9,93
-10 10,61
-5 11,30
0 12,00
α
[°]
I [mA]
5 12,70
10 13,39
15 14,07
20 14,74
25 15,38
30 16,00
35 16,59
40 17,14
45 17,66
50 18,13
55 18,55
60 18,93
65 19,25
70 19,52
75 19,73
80 19,88
85 19,97
90 20,00
Angle and output values:
output curr
ent I [mA]
angle of inclination
α
[°]