2  Safety instructions

•  Read this document before setting up the product and keep it during the entire 

service life�

•  The product must be suitable for the corresponding applications and 

environmental conditions without any restrictions�

•  Only use the product for its intended purpose 

(→ 3 Functions and features)

•  If the operating instructions or the technical data are not adhered to, personal 

injury and/or damage to property may occur� 

•  The manufacturer assumes no liability or warranty for any consequences 

caused by tampering with the product or incorrect use by the operator�

•  Installation, electrical connection, set-up, operation and maintenance of the 

product must be carried out by qualified personnel authorised by the machine 

operator�

•  Protect units and cables against damage�

3  Functions and features

The unit is used to visually display machine conditions� The versions DVx510 and 

DVx530 additionally have a buzzer for acoustic signalling�
The 5 LED segments and the audible warning device can be switched on and off 

individually�

 

The device is intended for indoor use only� 

Observe the operating conditions 

(→ 11 Technical data)

 

The unit must not be used for safety-related applications such as 

access control�

The standard units are DV15xx� The DV25xx units are IO-Link devices� The 

IO-Link version can be triggered and configured via the standard IO-Link 

interface� With the standard version the individual LED segments can be switched 

individually via digital inputs� Parameters are set via a parameter setting button or 

via an additional IO-Link interface�
If the equipment is used in a manner not specified by the manufacturer, the 

protection provided by the equipment may be impaired�

Summary of Contents for DV15 Series

Page 1: ...Operating instructions 5 segment signal lamp DV15x0 DV25x0 80263024 00 07 2019 UK...

Page 2: ...tion 8 6 1 IO Link device DV25x0 8 6 2 Standard device DV15x0 8 7 Operating and display elements 9 8 Operation 10 8 1 Operation of the IO Link version 10 8 1 1 General 10 8 1 2 On off mode 10 8 1 3 RG...

Page 3: ...3 UK 11 Technical data 21 11 1 IO Link device 21 12 Maintenance repair and disposal 22 12 1 Cleaning the housing surface 22 13 Approvals standards 22...

Page 4: ...on of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note WARNING Warning of serious personal injury Deat...

Page 5: ...ect units and cables against damage 3 Functions and features The unit is used to visually display machine conditions The versions DVx510 and DVx530 additionally have a buzzer for acoustic signalling T...

Page 6: ...e unit detailed information about process data structure diagnostic information parameter addresses and the necessary information about the required IO Link hardware and software can be found at www i...

Page 7: ...to fix it Observe the maximum tightening torque of the connection cable Integrated seals at the bottom of the fixture and in the base as well as O rings at the fixture and base prevent ingress of mois...

Page 8: ...t 5 2 buzzer DV1510 and DV1530 3 LED segment 3 4 LED segment 2 5 voltage supply 6 LED segment 1 7 LED segment 4 8 IO Link 6 2 1 4 5 7 3 8 The input polarity is selectable Connect pin 5 to 24 V DC to t...

Page 9: ...Parameter setting button only DV15x0 2 LED segment 1 with 4 RGB LEDs 3 LED segment 2 with 4 RGB LEDs 4 LED segment 3 with 4 RGB LEDs 5 LED segment 4 with 4 RGB LEDs 6 LED segment 5 with 4 RGB LEDs 7 B...

Page 10: ...r only with DVx510 and DVx530 on and off PDout cyclical data communication Signalling corresponds to the pre defined parameters for the individual LED segments and the buzzer Via the acyclic parameter...

Page 11: ...1 blue Byte 0 Segment 2 LED properties Seg 2 yellow Seg 2 red Seg 2 green Seg 2 blue Byte 1 Segment 3 LED properties Seg 3 yellow Seg 3 red Seg 3 green Seg 3 blue Byte 2 Segment 4 LED properties Seg...

Page 12: ...the controller transmits an analogue value between 0 and 100 in byte 0 via PDout Byte 1 determines the representation of the visual signalling 9 different representations are possible Byte 5 defines...

Page 13: ...white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white Segment 5 Seg...

Page 14: ...equency permanently on low flash rate slow medium fast high flash rate slow medium fast Brightness 100 75 50 25 Parameter setting via the IO Link interface pin 8 of the M12 connector is also possible...

Page 15: ...g button 5 s to change the value for the selected parameter Repeat this step until the requested setting is selected The unit indicates the current settings of the LED segment to be configured Press t...

Page 16: ...ss 100 75 50 25 3 Colour red green orange blue violet turquoise white yellow off Frequency on lowflash rate slow lowflash rate medium lowflash ratefast high flashrate slow high flashrate medium high f...

Page 17: ...17 UK 10 Scale drawing 10 1 DVx500 EPS Source Product Scale Draw Frame Size 80 mm Original Scale Draw Z_e200_0097 Scale 1 2 M4x1 70 344 213 17 100 25 14 M12x1 15 18 40 Dimensions mm...

Page 18: ...18 10 2 DVx510 EPS Source Product Scale Drawing Frame Size 80 mm x 90 Original Scale Drawing M 0_0096 Scale 1 2 70 384 213 57 100 25 14 M4x1 1 M12x1 15 18 40 1 Buzzer Dimensions mm...

Page 19: ...19 UK 10 3 DVx520 EPS Source Product Scale Dra Frame Size 80 mm Original Scale Draw Z_e200_0099 Scale 1 2 M4x1 70 244 213 17 15 14 M12x1 18 40 M4x1 70 244 213 17 15 14 Dimensions mm...

Page 20: ...20 10 4 DVx530 EPS Source Product Scale Drawing Frame Size 80 mm x 72 70 284 213 57 15 14 M4x1 1 M12x1 18 40 284 213 1 1 Buzzer Dimensions mm...

Page 21: ...50 Storage temperature C 40 75 Max permissible relative humidity 90 Maximum operating altitude m 2000 above sea level Permissible air pressure hPa 1060 IO Link Connectors M12 connector 8 poles M12 con...

Page 22: ...the applicable national regulations 12 1 Cleaning the housing surface Disconnect the device Clean the device from dirt using a soft chemically untreated and dry cloth In case of heavy dirt use a damp...