background image

Operating instructions 

RFID compact unit

DTE801/DTE802/DTE804/DTE805
DTE901/DTE902/DTE904/DTE905

80291447 / 00

 

07 / 2020

UK

Summary of Contents for DTE801

Page 1: ...Operating instructions RFID compact unit DTE801 DTE802 DTE804 DTE805 DTE901 DTE902 DTE904 DTE905 80291447 00 07 2020 UK ...

Page 2: ...04 8 5 7 Overview DTE904 8 5 8 Overview DTE805 8 5 9 Overview DTE905 9 6 Installation 9 6 1 General installation instructions 9 6 2 Notes on ID tag mounting 9 6 3 Avoiding interference 10 6 4 Mechanical design 10 6 5 Mounting options 10 6 5 1 Installation with angle bracket E80335 11 6 5 2 Installation with mounting device E80336 11 6 5 3 Installation with fixing bars E80337 12 6 6 Mounting distan...

Page 3: ...dicators DTE801 DTE901 19 8 3 1 LED SF 19 8 3 2 LED BF 19 8 4 LED indicators DTE802 DTE902 20 8 4 1 LED Mod module status 20 8 4 2 LED Net network status 21 8 5 LED indicators DTE804 DTE805 DTE904 DTE905 22 8 5 1 LED SF 22 8 5 2 LED BF 22 9 Maintenance repair and disposal 23 10 Approvals standards 23 10 1 Radio approvals 23 10 1 1 Overview 23 10 1 2 Europe EU declaration of conformity 23 10 1 3 US...

Page 4: ...reproduced and used without the consent of ifm electronic gmbh All product names pictures companies or other brands used on our pages are the property of the respective rights owners 2 Safety instructions The device described is a subcomponent for integration into a system The system architect is responsible for the safety of the system The system architect undertakes to perform a risk assessment ...

Page 5: ... against damage Use the device outside petrol stations fuel depots chemical plants or blasting operations Do not transport and store any flammable gases liquids or explosive substances near the unit Contact the manufacturer of the corresponding device in case of any interference Because of the requirements for electromagnetic interference emissions the device is intended for use in industrial envi...

Page 6: ... TCP IP Transport Control Protocol Internet Protocol IT functionality HTTP server M12 twisted pair 4 Items supplied DTE RFID compact unit Operating instructions The device is supplied without installation and connection accessories In the event of incomplete or damaged items supplied please contact ifm electronic 5 Function 5 1 Operating principle The ID tags are operated passively i e without bat...

Page 7: ...on Operating frequency Design Typ transm power DTE801 RFID compact unit DTRUHFE HLRWPNUS04 865 868 MHz rectangular 22 5 dBm ERP 178 mW 5 3 Overview DTE901 Art no Function Type designation Operating frequency Design Typ transm power DTE901 RFID compact unit DTRUHFA HLRWPNUS04 902 928 MHz rectangular 21 5 dBm EIRP 141 mW 5 4 Overview DTE802 Art no Function Type designation Operating frequency Design...

Page 8: ... transm power DTE804 RFID compact unit DTRUHFE HLRWENUS04 865 868 MHz rectangular 22 5 dBm ERP 178 mW 5 7 Overview DTE904 Art no Function Type designation Operating frequency Design Typ transm power DTE904 RFID compact unit DTRUHFA HLRWENUS04 902 928 MHz rectangular 21 5 dBm EIRP 141 mW 5 8 Overview DTE805 Art no Function Type designation Operating frequency Design Typ transm power DTE805 RFID com...

Page 9: ...neral installation instructions Devices installed next to each other interfere if they are not configured correspondingly When mounting several RFID compact units adhere to the minimum distances between the systems Installing a unit in or on metal reduces the read and write distance The immediate vicinity of powerful HF emission sources such as welding transformers or converters can affect operati...

Page 10: ...e operated in its vicinity Use in alternating operation Switch on off the HF field During a read or write operation there must not be any objects or persons between the device and an ID tag as this has a strong damping influence on the UHF field 6 4 Mechanical design 1 2 1 Sensing face 2 Connections can be rotated by 270 6 5 Mounting options For installation the following optional accessories are ...

Page 11: ...35 6 5 2 Installation with mounting device E80336 The mounting device is used to mount the device to a clamp The following clamps can be used E21110 with a rod diameter of 12 mm E20795 with a rod diameter of 14 mm E21109 with a rod diameter of 14 mm ...

Page 12: ...ng screws to the designated location 6 6 Mounting distances Operating mode Distance side A Distance front B Reading and writing at 100 transmitting power simultaneous operation 6 0 m 10 0 m Reading and writing at 100 transmitting power alternating operation 0 3 m 0 3 m ...

Page 13: ...nnected by a qualified electrician Device of protection class III PC III The electric supply must only be made via SELV circuits Disconnect power before connecting the device For cable lengths 30 m use an additional protection against surge voltages to IEC 61000 4 5 NOTE The IP rating indicated in the data sheet is only guaranteed if the M12 connectors are firmly screwed The device can be damaged ...

Page 14: ...ital input output 2 3 0 V 4 Digital input output 1 5 Not connected Pin connection voltage supply 7 2 Ethernet Connect the device to a PC using a suitable M12 Ethernet connection cable The M12 Ethernet cable must be screened to ensure interference free operation 1 2 3 4 Pin Connection 1 TD 2 RD 3 TD 4 RD Pin connection fieldbus connection ...

Page 15: ...n On DHCP Off The settings can be changed via the unit s web server or via the PC 7 3 Functional earth connection To ensure interference free operation the unit must be connected to an earth potential free from external voltage 7 3 1 Mounting plate When the unit is fixed on a mounting plate the connection is made via one of the four mounting bolts on the back Note that the plate must be connected ...

Page 16: ...n electrically conductive bridge between pin 2 and pin 4 on the process connection voltage supply PWR Connect the unit to the voltage supply The LEDs of the signal bar yellow are on one after the other Then LED 4 of the signal bar yellow flashes at 8 Hz As soon as the LEDs of the signal bar yellow flash at 8 Hz disconnect the unit Remove the bridge Connect the unit to the voltage supply The settin...

Page 17: ...written incorrectly If the ID tag has a high receive signal strength all LEDs of the signal bar are on configurable The maximum receive signal strength depends on the type of the ID tag 8 2 2 LED signal bar LED signal bar LED 1 LED signal bar LED 2 LED signal bar LED 3 LED signal bar LED 4 State Off Off Off Off No ID tag detected On Off Off Off 1 ID tag detected On On Off Off 2 ID tags detected On...

Page 18: ...8 2 4 Special device LED indicators LED State Note PWR LED green on LEDs of signal bar yellow flashing at 8 Hz Device is in the service mode emergency system started A firmware update is necessary and can be executed via the web server PWR LED green on LEDs of signal bar yellow flashing at 8 Hz Major error device has to be returned Hardware fault or permanent data in the device are corrupt PWR LED...

Page 19: ...rnal fault On Off Error at device level Temperature Flashes Flashes Self test Starting phase of the device 8 3 2 LED BF LED red LED green State Note Off Off No voltage supply Check the voltage supply Off Flashes PROFINET IO controller is in STOP mode Off On PROFINET IO controller is in RUN mode Flashes Off Connection to the PROFINET IO controller is established no valid configuration Check configu...

Page 20: ...IP scanner Check the parameter setting of the configuration assembly Off On Normal operation Connection to the EtherNet IP scanner is established The device is configured The data transfer is running Flashes Off Minor error A connection to the EtherNet IP scanner was not established Check the voltage supply Check the configuration of the device On Off Major error Software hardware error of the dev...

Page 21: ...d Check the configuration of the device via EtherNet IP scanner Off On connection available At least one EtherNet IP connection to the device was established Flashes Off Timeout of the connection A timeout was found with one of the existing EtherNet IP connections Check the status of the connection in the EtherNet IP scanner On Off IP address exists already The same IP address as that of the devic...

Page 22: ... level Temperature Flashes Flashes Self test Starting phase of the device 8 5 2 LED BF LED red LED green State Note Off Off No voltage supply Check the voltage supply Off Flashes Connection to host Controller exists there is no data exchange Off On Connection to host Controller exists data exchange running Flashes Off Connection to host Controller exists there is no valid configuration Check confi...

Page 23: ...oval status of a device is available on our website at www ifm com 10 1 2 Europe EU declaration of conformity ifm electronic gmbh hereby declares that the DTE80x DTE90x radio system corresponds to the directive 2014 53 EU You can find the EU declaration of conformity at the following Internet address www ifm com 10 1 3 USA FCC note This device complies with Part 15 of the FCC Rules Operation is su...

Page 24: ...use interference and 2 the user of this device must accept any interference received including interference that may cause undesired operation 3 The distance between the read write head and an ID tag must be 20 cm 10 1 5 Taiwan Administrative Regulations on low power radio wave devices Article 12 Unless granted permission by NCC no company firm or user shall alter the frequency increase the transm...

Page 25: ...功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現有干擾現象 時 應立即停用 並改善至無干擾時方得繼續使用 前項合法通信 指依電信法規定作業之無線電通信 低功率射頻電機須忍受合法通信或工業 科學及醫療用電波輻射性電機設備之干擾 10 1 6 Australia Use in Australia 10 1 7 Singapore Complies with IDA Standards DB 103032 The Equipment Registration is available on our website at www ifm com 11 Scale drawing 64 12 5 88 12 4 50 113 113 120 34 34 M12x1 ...

Page 26: ...26 ...

Page 27: ...27 UK ...