IO-Link data memory
DSU100
13
The data in the process image is updated as soon as the memory contents change. The data in the
process image is valid as soon as the status bit "Cmd End" is set.
Byte
Process data output
Process data input
0
command value = 0x01
command value = 0x01
1
status
status
2
ignored
data 0
3
ignored
data 1
4
ignored
data 2
5
ignored
data 3
6
ignored
data 4
7
ignored
data 5
8
ignored
data 6
9
ignored
data 7
10
ignored
data 8
11
ignored
data 9
12
ignored
data 10
13
ignored
data 11
14
ignored
data 12
15
ignored
data 13
16
ignored
data 14
17
ignored
data 15
18
ignored
data 16
19
ignored
data 17
20
ignored
data 18
21
ignored
data 19
22
ignored
data 20
23
ignored
data 21
24
ignored
data 22
25
ignored
data 23
26
ignored
data 24
27
ignored
data 25
28
ignored
data 26
29
ignored
data 27
30
ignored
0x00
31
ignored
error value
8.5 "Auto-write data” operating mode
In the "Auto-write data" operating mode the data to be written is defined by the process data output
image. The data is set by the parameters "Auto-Read/Write Address" and "Auto-Read/Write Data
Length".
Max. 28 bytes can be defined in the process data output image (data 0 to 27). If a shorter length is
defined in the parameter "Auto-Read/Write Data Length", the other data bytes are ignored and not
written to the internal memory.
If writing was successful, the written data is copied to the process data input image and the status bit
"Cmd End" is set.