Speed monitor
DP2122
23
•
[OFF] = indication in Hz with automatic decimal point setting.
•
[cccc] = indication without decimal place.
•
[ccc.c] = indication with 1 decimal place.
•
[cc.cc] = indication with 2 decimal places.
•
[c.ccc] = indication with 3 decimal places.
With a fixed display screen ([ScAL] ≠ OFF) only the decimal point is set. No automatic scaling
takes place.
C.FEP ─ custom user endpoint for frequency (
If [ScAL] is set to [cccc], [ccc.c], [cc.cc] or [c.ccc], decimal places of the frequency-dependent
process and parameter values cannot be displayed.
Depending on the scaling factor, the parameters can be set via the display with an accuracy of
0.5 Hz (C.FEP=4000) to 4 Hz (C.FEP=500).
8.6.5 C.FEP ─ custom user endpoint for frequency
Settings for scaled display values.\
The parameters are only displayed in operating mode 1 and when [ScAL] is set to [cccc], [ccc.c],
[cc.cc] or [c.ccc].
All displayed frequency/speed values are interpolated based on a 2-point approximation.
IO-Link process data and parameters are not influenced by scaling.
2
3
1
f [Hz]
C.FEP
2000
2000
200
4000
C.FEP
U(f) = f 2000 Hz
1:
Scaling factor 2
2:
Scaling factor 1
3:
Scaling factor 0.5
C.FEP max = 4000
U(f) corresponds to the scaled value
f corresponds to the value in Hz
8.6.6 PrSC ─ prescaler
Setting of the number of targets. The number of targets is automatically included in the measured
values.
Only active in operating mode 2.
8.6.7 coLr ─ display colours and colour changes
Assignment of the display colours "red" and "green" within the measuring range.