DP2122
Speed monitor
10
SP2
SP2
SP2-H
H
ON
SSC
SP1
SP1+H
SP1
H
OFF
ON
Fig. 7: NC (IO-Link parameter LoGc: nc / low active)
SP1:
switch-off point window
SP1+H: Switch-on point
SP2:
switch-off point window
SP2-H:
Switch-on point
If the set speed range is left, the swicthing signal will signal this as closed.
1:
Power-on delay time
2:
Start-up delay
3:
Normally open
4:
Normally closed
4.4.3 Two point mode
SP2
SP1
SP2
H
OFF
ON
SSC
SP1
Fig. 8: NO (IO-Link parameter LoGc: no / high active)
SP1: Overspeed: Switch point / underspeed: Reset point
SP2: Overspeed: Reset point / underspeed: Switch point
If a set rotational speed is not reached, this is signalled by the switching signal as open.
SP2
SP1
SP2
H
ON
SSC
SP1
OFF
Fig. 9: NC (IO-Link parameter LoGc: nc / low active)
SP1: Overspeed: Switch point / underspeed: Reset point
SP2: Overspeed: Reset point / underspeed: Switch point