![background image](http://html.mh-extra.com/html/ifm/dp1222/dp1222_operating-instructions-manual_620752006.webp)
DP1222
Converter 2 x 0...10 V / IO-Link
6
4 Function
The unit provides the IO-Link process data according to the analogue input signals.
The unit is designed for half-duplex communication. So the following options are possible:
•
Remote display: reading and displaying the current voltage value
•
Remote parameter setting: reading and changing the current parameter setting
•
IO-Link parameter setting: IO Device Description (IODD) (
4.1 Operating modes
The following operating modes are available:
Operating mode 1
Description
Operating mode for backwards compatibility
Please note that this operating mode does not support all
functionalities described in the instructions.
Application
To ensure compatibility if sensors are replaced
IODD designation
DP1222
IO-Link device ID
613d / 00 02 65 h
Operating mode 2 (default)
Description
Operating mode on delivery
Application
Standard application
IODD designation
DP1222_Status_B
IO-Link device ID
1428 d / 00 05 94 h
4.2 Application as an IO-Link device
4.2.1 General information
The unit has an IO-Link communication interface which requires an IO-Link capable module (IO-Link
master).
The IO-Link interface allows direct access to the process and diagnostic data and enables setting of
the parameters of the unit during operation.
You will find further information about IO-Link and all the necessary information about the required IO-
Link hardware and software at: