7 Set-up
When the device is switched on for the first time, it is necessary to configure the
overspeed frequency (Fo) using the three switches�
The 3 switches allow the user to enter the value of the desired preset frequency�
• With S1 and S2 switches numerical values from 1 to 99 can be set (S1 with
increments of 10, S2 with increments of 1)�
• DD110S: The multiplier is set using switch S3� The numerical values are
multiplied with these factors and thus provide the actual switch point value�
The multipliers have the unit "rpm" or Hz"�
DD111S: The decimal values can be set with switch S3�
7.1 Configuration position (factory setting)
The switch point value can only be set when the operating voltage is
connected to the device and the 3 switches are set as indicated (factory
setting)�
S2
rpm
1
50
100
10
PP
Hz
5
9
6
10
500
0,5 1
S3
9
6
3
3
P/0
P/0
S1
S2
S3
9
6
3
9
6
3
P/0
9
6
3
P/0
P/0
S1
DD110S
DD111S
S1 in position P/0
S2 in position P/0
S3 in position P (DD110S) or P/0 (DD111S)
ATTENTION!
To prevent damage to the switches use a screwdriver of the
appropriate size�