background image

CR3133

CANwireless

12

Function

Index

Subindex

Description

Activate / deactivate CAN-
open objects

0x20F4

0x00

This parameter defines whether the CANopen stack is activat-
ed or not:

0: CANopen remains active during connection (default)

1: The CANopen stack is disabled during connection.

If the CANopen stack is disabled during a radio connection, the device CANNOT be configured.

These messages are not sent if the CANopen stack is disabled:

Type

Index

Tx SDO 1

0x580 + node ID

Rx SDO 1

0x600 + node ID

Heartbeat / Bootup

0x700 + node ID

NMT

0x000

8.3.2 Factory reset

The following reset variants can be triggered via the CAN interface:

Function

Index

Subindex

Description

Reset device to factory set-
tings

0x1011

0x01

The factory configuration is restored. All recorded data is de-
leted.

Reset communication param-
eters to factory settings

0x1011

0x02

The following parameters are reset to factory settings:

- Node ID CAN1: 33

- Node ID CAN2: 34

- Baud rate CAN1: 3 (250 kbit/s)

- Baud rate CAN2: 3 (250 kbit/s)

- Heartbeat CAN1: 0 (no heartbeat)

- Heartbeat CAN2: 0 (no heartbeat)

- NMT startup CAN1: 0 (automatically set to operational)

Reset parameters defined by
the manufacturer to factory
settings

0x1011

0x19

The following parameters are reset to factory settings:

- CAN1 filter settings

- CAN1 mask settings

- CAN1 downsampling time

To carry out the factory reset via the CAN interface, CANopen software (e.g. maintenance tool) and a
communication gateway (e.g. CANfox, part no. EC2112) are required. The CANopen software writes
the value 0x64616F6C into the CANopen object index 0x1011, subindex 0x01, to perform a complete
reset.

The following example shows the factory reset via the subindex 0x01 (restoration of the default
configuration):

u

Connect the device with a PC 

Connecting the device (

Ò

 

/

 11)

.

u

Start the CANopen software.

u

Write the value 0x64616F6C into the object index 0x1011, subindex 0x01 via the CANopen
software.

u

Write the value to the object directory of the device.

w

The ON and STATUS LEDs both light orange.

w

The device is reset to factory settings.

u

Wait until the STATUS LED flashes green.

w

The STATUS LED flashes green.

w

The device is reset to factory settings.

Summary of Contents for CR3133

Page 1: ...Operating instructions CANwireless CR3133 11515548 00 04 2023 GB...

Page 2: ...nna terminal 8 7 Light indicators 9 7 1 ON LED 9 7 2 STATUS LED 9 8 Set up 11 8 1 Necessary components 11 8 2 Connecting the device 11 8 3 Configuration 11 8 3 1 CANopen 11 8 3 2 Factory reset 12 8 3...

Page 3: ...tructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings...

Page 4: ...g instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering w...

Page 5: ...of CAN data of a vehicle or machine via a WLAN or a Bluetooth interface to another CANwireless device or to any Bluetooth device Available modes are a CAN bridge to another machine or a direct wireles...

Page 6: ...on to other Bluetooth devices such as smartphones tablets or laptops The CAN data is transferred to the connected device and can be stored and evaluated there The CAN data is formatted with the Byte C...

Page 7: ...chnical data and safety will be impaired 54 Fig 1 Holes for mounting u Use 2 M6x30 cylinder head bolts to fix the device on an even surface Tightening torque 3 4 Nm 10 5 1 Mounting the antennas u When...

Page 8: ...g 1 input 3 GND terminal 31 supply 4 analogue input 1 5 analogue input 2 6 not used 7 digital output 8 digital input terminal 15 input ignition signal 9 factory setting 2 input 10 GND terminal 31 supp...

Page 9: ...ermissible range Orange On The device is reset to factory settings The ON and STATUS LEDs are lit simultaneously Turquoise On The radio module is being updated via HTTP server The ON and STATUS LEDs a...

Page 10: ...LEDs flash simultaneously Blue Flashing Data is being transferred Blue On Wireless connection error Orange Single flashing light The device has received a CANopen SDO request Orange On Error CAN1 Red...

Page 11: ...erminating resistors u Connect the CAN PC interface with the CAN adapter cable to the device and connect it to the PC u Connect the ground terminal of the power supply to CAN1 GND u Apply the supply v...

Page 12: ...AN2 3 250 kbit s Heartbeat CAN1 0 no heartbeat Heartbeat CAN2 0 no heartbeat NMT startup CAN1 0 automatically set to operational Reset parameters defined by the manufacturer to factory settings 0x1011...

Page 13: ...N ID is identified as authorised MaskValue Mask with which a CAN ID is identified as authorised The verification mechanism works as follows RxCANid XOR FilterValue checkedCANid checkedCANid AND MaskVa...

Page 14: ...FilterValue Description Hex Binary Received CAN message 1 0x123 0b001 0010 0011 Received CAN message 2 0x124 0b001 0010 0100 Received CAN message 3 0x125 0b001 0010 0101 OR Required value for FilterVa...

Page 15: ...4 and 0x627 0x628 0x629 Two filters and masks should be used here for the 0x1 IDs and the 0x62 IDs respectively Description Hex Binary 0x10 0b001 0000 0x11 0b001 0001 0x12 0b001 0010 0x13 0b001 0011 0...

Page 16: ...bject in which the FilterValue for the eight filters is configured This setting is taken over directly from the filter and can be ad justed dynamically The filter is only active when the radio interfa...

Page 17: ...dex Data type Configuration WLAN Enable 0x3008 0x02 Unsigned 8 0 switch off Bluetooth Enable 0x3008 0x03 Unsigned 8 1 switch on Bluetooth Devicename 0x3002 0x05 Visible_string Enter a unique name Blue...

Page 18: ...CAN bridge via WLAN Mini Access Point MiniAP mode In this mode a wireless connection CAN bridge is established between two CANwireless devices via WLAN The devices need to be configured as follows Ob...

Page 19: ...ure 8 3 10 CAN Mobile device PC interface P2P WLAN Mini Access Point In this mode a wireless connection is established between a CANwireless device and any other WLAN enabled device via WLAN The CANwi...

Page 20: ...1 0x3010 0x01 Unsigned 8 2 connect with static address Client Enable 0x3010 0x15 Unsigned 8 3 turn on client Server Type 0x3010 0x16 Unsigned 8 1 socket TCP UDP Server Type 0x3010 0x18 Unsigned 16 30...

Page 21: ...ep mode are met it will be enforced when this time has elapsed This ensures switchover to sleep mode even if the regular activation of this mode should fail Default 60000 PMM Sleep on no CAN time non...

Page 22: ...in case of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the device...

Reviews: