background image

2

1  Preliminary note

Technical data, approvals, accessories and further information at 
www.ifm.com.

2  Safety instructions

•  The device described is a subcomponent for integration into a system.

 - The manufacturer is responsible for the safety of the system.
 - The system manufacturer undertakes to perform a risk assessment and to 

create a documentation in accordance with legal and normative requirements 
to be provided to the operator and user of the system. This documentation 
must contain all necessary information and safety instructions for the operator, 
the user and, if applicable, for any service personnel authorised by the 
manufacturer of the system.

•  Read this document before setting up the product and keep it during the entire 

service life.

•  The product must be suitable for the corresponding applications and 

environmental conditions without any restrictions.

•  Only use the product for its intended purpose (→ Functions and features).
•  If the operating instructions or the technical data are not adhered to, personal 

injury and/or damage to property may occur. 

•  The manufacturer assumes no liability or warranty for any consequences 

caused by tampering with the product or incorrect use by the operator.

•  Installation, electrical connection, set-up, programming, configuration, operation 

and maintenance of the product must be carried out by personnel qualified and 
authorised for the respective activity.

•  Protect units and cables against damage.

3  Functions and features

The IO-Link master modules serve as a gateway between intelligent IO-Link 
sensors and the field bus. The units with protection rating IP 20 are designed as a 
control cabinet module for use in plant construction. 

4  Symbols used

Instruction

Summary of Contents for AL19 Series

Page 1: ...Operating instructions IO Link master AL19xx 80281466 00 01 2019 UK...

Page 2: ...roduct must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose Functions and features If the operating i...

Page 3: ...inst accidental contact with dangerous contact voltages and against external influence The control cabinet has to be installed in accordance with local and national regulations Mount the unit vertical...

Page 4: ...ice surfaces that could be touched by means of basic insulation according to IEC 61010 1 secondary circuit with max operating voltage supplied from mains circuit up to 300 V of overvoltage category II...

Page 5: ...4 V DC US AL1900 AL1920 AL1930 AL1940 AL1950 RJ45 PROFINET Ethernet port X21 X22 EtherNet IP Ethernet port X21 X22 EtherCAT Ethernet port X21 X22 Modbus TCP Ethernet port X21 X22 RJ45 IoT Internet of...

Page 6: ...ltage supply Voltage supply Voltage supply Voltage supply 2 8 IO Link A ports 8 IO Link A ports 8 IO Link A ports 8 IO Link A ports 8 IO Link A ports 3 PROFINET IO EtherNet IP EtherCAT Modbus TCP 4 Io...

Page 7: ...0 0 0 MAC address See type label 8 Parameter setting The parameter setting and configuration of the field bus interface is done via the higher level PLC As an option the connected IO Link devices can...

Page 8: ...8 10 Scale drawing 50 125 7 35 105 3 100 6 AL1900 AL1920 AL1930 AL1940 AL1950 50 125 7 35 105 3 100 6...

Page 9: ...9 UK 10 1 Terminal arrangement X01 X02 X03 X04 X31 X08 X07 X06 X05 AL1900 AL1920 AL1930 AL1940 X01 X02 X03 X04 X31 X08 X07 X06 X05 AL1950 AL1950...

Page 10: ...Protection class III Sensor supply US Total current rating A 3 6 Environmental conditions Application Control cabinet Ambient temperature C 25 65 Storage temperature C 25 85 Max perm relative air hum...