12
8.2 Configuration in the AS-Interface safety monitor
Refer to the operating instructions of the AS-Interface safety monitor and the data
bit table�
Configure the safety switch in the AS-Interface safety monitor with the set
AS-Interface address, for example, as follows:
Dual-channel dependent
-
synchronisation time = infinite (∞)
In this operating mode, the safety guard must be opened each time prior to
restarting in order to perform the start-up test�
Dual-channel independent
The guard locking is opened or closed via the output D0� When the guard locking
is open, the safety circuit shuts down� It is not necessary to open the door� Safety
is provided again when the guard locking is closed�
The dual-channel feature and the door contact are not tested in this configuration�
Take additional measures for testing outside the monitor�
8.2.1 Monitor with extended functions
For the monitor with extended functions the following configuration is possible:
-dual-channel conditionally dependent
-independent: In-1
The guard locking is opened or closed via the output D0� When the guard locking
is open, the safety circuit shuts down� It is not necessary to open the door� Safety
is provided again when the guard locking is closed�
The switch is monitored for malfunction, the door contact (SK) must not switch
before the guard locking contact (ÜK)�
Status signals (not relevant to safety)
The status of the AS-Interface input bits D0 and D1 for door monitoring and the
AS-Interface input bits D2 and D3 for solenoid monitoring can also be requested
via the controller (PLC) (see operating instructions AS-Interface safety monitor)�