Mount the safety switch positively�
►
Permanently connect the actuator to the safety guard so that it cannot be
detached (e�g� using the enclosed non-removable screws), alternatively rivet
or weld�
►
Fit an additional end stop for the movable part of the safety guard�
Observe EN ISO 14119:2013, sections 5�2 and 5�3, on mounting of a safety
switch and an actuator�
Observe EN ISO 14119:2013, section 7, on measures to reduce the
possibilities of bypassing�
6.1.1 Changing the actuating direction
A
D
B
C
►
Remove the screws from the actuating head�
►
Set the required direction�
►
Tighten the screws with 0�6 Nm�
►
Close the unused actuating slots with the supplied slot covers�