7
The switches are equipped with a red, mushroom-shaped E-stop button. Check the
individual emergency stop switches and reset them to ensure proper functioning of the
control circuits.
The typical operating conditions for a successful operation of the safety rope
emergency stop system are:
max. 75N pull force and max. 150mm bending of the rope between the eye bolts for
rope support.
Rope pull systems with
single
direction safety rope emergency stop switches are
influenced by fluctuations of the ambient temperature!
To ensure proper function of the rope pull system it is mandatory to take into account
the dependence on the temperature when fixing the rope length and distance of the
eye bolts (every 3m).
+ 25°C
+ 22°C
+ 20°C
+ 15°C
+ 10°C
+ 7,5°C
+ 5°C
+ 3°C
Installation Temperature [°C]
- 3°C
- 5°C
- 7,5°C
- 10°C
- 15°C
- 20°C
- 22°C
- 25°C
Rope Length
15m
30m
50m
60m
75m
100m
126m
Installation Temperature in [°C] ±
X
[°C] = max. allowed rope length in [m]
Not OK
OK