6
5 Electrical connection
The unit must be connected by a qualified electrician
The national and international regulations for the installation of electri-
►
cal equipment must be adhered to
Voltage supply according to EN 50178
►
Disconnect power
►
Connect the unit as follows:
►
Receiver DC PNP
Receiver DC NPN
L
L+
3
2
4
1
teach
L
L+
3
2
4
1
teach
Transmitter DC
1
3
L+
L
Programming of the output function by pushbutton or programming wire
(→ 7.5 Programming the output function).
6 Setup
The through-beam sensor is supplied ready to operate (plug & play) set at the
max sensing range This is sufficient if the through-beam sensor can operate with
maximum excess gain The following setting procedures should only be necessary
in less straight-forward applications, for example if partly transparent objects must
be detected