9 Installation
9.1 Installation location
The operating principle of the antenna is influenced by the type of installation and
the environment�
Observe the following remarks for the selection of the installation location:
●
Keep a distance of min� 70 cm to metal surfaces and the ground (see Figure 1)�
●
When installed in front of a metal surface, use a mounting bracket that
establishes a distance of exactly 12 cm between the back of the device and the
metal surface (see Figure 2)�
●
With direct installation on a metal surface (e�g� a plate as part of
a mounting bracket) use a square-shaped metal plate with the dimensions
16 x 16 cm (see Figure 3)�
●
Avoid conductive objects such as tanks with liquids in the vicinity of the
installation location� The objects influence the performance of the antenna�
●
Ensure sufficient heat dissipation at the installation location� The maximum
operating temperature indicated in the data sheet must not be exceeded�
min 70 cm
min 70 cm
min 70 cm
min 70 cm
12 cm
max 16 cm
max 16 cm
Figure 1: Distance to all sides min� 70 cm
Figure 2: Distance
between device and
metal surface
exactly 12 cm
Figure 3:
Metal surface with
max� 16 cm x 16 cm
If the installation instructions are not adhered to, the antenna characteristics