4. Operating and indicating elements
MONITOR
FS-2 / FS-2N
PAGE
22
1
4
6
5
2
19
20
21
22
23
24
13
14
15
16
17
18
3
9
7
8
10
11
12
MONITOR FS-2 N
Slip monitor
Out1
Out2
In 1
3
2
5
6
4
CH1CH2 CH3 CH4 RUNPRG TST KEY
In 2
Err
CH1CH2 CH3 CH4RUNPRG TST KEY
1a
1b
1c
1
1
Display (7/14-segment)
1a Indicators for input channels and operating modes:
CH1...CH4
Input channels (here: CH1 and CH2)
RUN
Run mode (normal operating mode)
PRG
Programming mode (setting of the parameter values)
TST
Test function (only optional)
KEY
Status of the unit (locking)
1b Indication:
Actual values and parameter values (5-digit, numerical)
slip: 0.1...99.9%, rotational speed: 0...60,000 RPM,
pulses: 0.1...1000.0 Hz
Outside the value ranges the display shows "----".
1c Indication:
Parameter abbreviation and units (3-digit, alphanumeric)
2
Push buttons / :
Selection of the actual value display, parameter selection,
setting of the parameter values
3
Push button :
Selection of the operating mode,
acknowledgement of the parameter value, front reset
4
LEDs In1/2 (yellow): indicate input pulses
LED Err (red):
(only FS-2N) lights in case of wire break or short circuit on the cable of the
pulse pick-up, at the same time the CH indicator of the faulty input flashes
5
LEDs Out1/2 (green): Switching status of the outputs 1 and 2
Off:
The output is not switched (relay de-energised, transistor blocked)
On:
The output is switched (relay energised, transistor switched)
Quickly flashing:
The output is kept latched (parameter SOP, Store Output)
Slowly flashing:
The delay time is effective for the output. The output switches when the
delay time has elapsed and the trigger event is still present
(parameter DTx, Delay Time)
6
Panel for labelling