INPUT
/
OUTPUT MODULE
CR2513
PAGE
30
Wiring
(with configuration examples)
.
Digital
z.B. Wegeventil
PWM
z.B. Proportionalventil
Supply
DC
Supply GND
23
VBB
S
01
GND
S
05
38
20
DC
Channel 1
BH
+VBB
O
CAN
Interface
CAN_GND
50
15
14
32
33
51
CAN_H
CAN_L
CAN_H
CAN_L
CAN_GND
GND
49
16
29
Channel 12
A
GND
48
34
10
Channel 11
A
GND
47
25
28
Channel 10
A
GND
46
04
09
Channel 9
A
GND
53
17
30
Channel 8
BL
GND
52
35
11
Channel 7
BL
GND
41
22
27
Channel 6
BL
GND
40
12
08
Channel 5
BL
+VBB
S
+VBB
S
+VBB
S
+VBB
S
+VBB
S
+VBB
S
+VBB
S
+VBB
S
VBB
O
43
39
21
Channel 2
RC
BH
+VBB
O
44
54
36
Channel 3
RC
BH
+VBB
O
45
55
37
Channel 4
RC
BH
+VBB
O
02
GND
RC
42
03
GND
18
GND
19
GND
Outputs
Inputs
Danfoss
Typ PVEH/S/M
(RC-Tiefpassfilter)
+
–
Explanation of the abbreviations:
A
= analog
BH
= binary high side
BL
= binary low side
RC
= RC low-pass filter for Danfoss valves
VBB
O
= power supply outputs
VBB
S
= power supply sensors/module
digital
e.g. two-way valves
digital
e.g. two-way valves
PWM
e.g. proportional valves
Danfoss
type PVEH/S/M
(RC low-pass filter)
For safety reasons the
valve is supplied with
voltage via a binary out-
put.