IES EC 12 Operator'S Manual Download Page 5

5. DEL-T MENU SETTINGS* 

 

*To enter DEL-T menu press 

DEL

 and 

T

 for 

5seconds. 
 

5.1 SELECT DIMMERCURVE 

After activation of the Del T menu the display show 
C-(x). X will show the active curve. The EC dimmer 
recognizes 8 curves. The curve selection is a global 
setting and cannot be set for each channel 
individually. 
Via the U key the number after the C can be 
incremented to the value, dimming curve needed. 
Dimmer curves available are: 
  0 = s-log curve *  
  1 = linear 
  2 = square 
  3 = fluorescent 
  4 = TV light 
  5 = future use 
  6 = future use 
  7 = future use 
 
* Factory default is the S-log curve.  

5.2 DMX 512 BACK-UP FACILITY 

This menu behaves like a dipswitch setting. Each 
channel represents a switch. If the channel LED is 
on it represents an on state. Normally if the DMX 
data fails the control value is set to zero after 30 
seconds. The following functions can be selected: 
 

 

Channel one: 

Disable (off), Enable (on) 
The last valid data will be retained. 
 

 

Channel two: 

Disable (off), Enable (on) 
If the DMX signal fails the backup scene will be 
activated. To program this scene, make the desired 
setting by means of a DMX signal. Then turn on 
channel two and leave the menu with the “H” button. 
This scene is now recorded. 
 

 

Channel three: 

Disable (off), Enable (on) 
Exhibition mode. This means that a setting can be 
made with the channel buttons, and automatically 
recorded after 60 seconds. 
 
This menu can be left by pressing the “H” button. 
 
 
 
 
 
 

6. DEL-U MENU SETTINGS* 

 

*To enter DEL-U menu press 

DEL

 and 

U

 for 

5seconds. 
 

6.1 SERIAL COMMUNICATION 

The Del U menu controls parameters for SERIAL 
communication with a PC. This menu is a dipswitch 
menu. To enter the Del U menu, press the Del and 
U key over 5 second simultaneously. Each channel 
represents an on state. The following functions, 
parameters can be altered. 
 
Channel one   :  Enable (on) Disable (off) 
Communication 
Channel two   :  Enable (on) Disable (off) 
Monitor data transfer 
Channel three :  Enable (on) Disable (off) 
Bi-directional serial control 
Channel four   :  Enable (on) Disable (off) 
Error monitoring 
Channel five    :  Enable (on) Disable (off) 
Error monitoring 
Channel five    :  Enable (on) Disable (off) 
Currently not used 
Channel six     :  Enable (on) Disable (off) 
Currently not used 
 
 
When the Del U menu is activated and the serial 
communication is enabled the display will show the 
valid information about the PC-communication 
address. Default value for the PC is 00. This 
address must be a unique number and is not related 
to the DMX address. To set the PC address use the 
H, T, U buttons. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

IES EC24 & EC12 dimmer pack Operators’ Manual v. 1.0          

20-10-2003

 5 

Summary of Contents for EC 12

Page 1: ...4 Safety 2 3 Control panel layout 3 4 Function DEL H MENU 4 4 1 Adjusting minimum output 4 4 2 Adjusting maximum output 4 4 3 Select Solid state function 4 4 4 Adjusting delay times 4 5 Function DEL T MENU 5 5 1 Select Dimmer curve 5 5 2 DMX 512 Back up facility 5 6 Function DEL U MENU 5 6 1 Serial communication 5 7 Return to factory settings 6 8 Dimmer overview 7 9 Specifications 8 10 Declaration...

Page 2: ... simply made by fitting the appropriate plug to the load cable 2 3 3 DMX data signal connections The dimmers are controlled using DMX 512 This is connected by a two pair and shield high speed data cable with XLR 5 pin connectors male input female output Pin connections are 1 0V shield 2 DMX 3 DMX 4 DATA 5 DATA The DMX network supports up to 32 PR 6 dimmer packs 192 dimmers in total connected to ea...

Page 3: ...ress the DEL button within 5 seconds the min and max buttons The displayed values should be written including frequency and software number if You might encounter any problem Your dealers need information to assist in an adequate way H Selects the hundreds T Selects the tenths U Selects the units CHANNEL BUTTON AND INDICATION Use these key s to adjust the output level between 0 25 50 75 100 Led s ...

Page 4: ... or max key 4 3 SELECT SOLIDSTATE FUNCTION Each dimmer channel can function as a dimmer or as a switch solid state channel zero crossing To select the switch function enter the maximum channel output adjustment using the key sequence del H and max The switch function is active if the maximum output is set to 100 Adjust the display until it indicates until it indicates 99 9 Now press the U key The ...

Page 5: ...scene is now recorded Channel three Disable off Enable on Exhibition mode This means that a setting can be made with the channel buttons and automatically recorded after 60 seconds This menu can be left by pressing the H button 6 DEL U MENU SETTINGS To enter DEL U menu press DEL and U for 5seconds 6 1 SERIAL COMMUNICATION The Del U menu controls parameters for SERIAL communication with a PC This m...

Page 6: ... RETURN TO FACTORY SETTINGS To return to the factory settings Make the dipswitch setting at the inside off the EC dimmer as below When dipswitch is placed remove power from EC dimmer Plug in Power again Display shows 555 Dipswitch settings normal use Dipswitch setting to reset the EC dimmer IES EC24 EC12 dimmer pack Operators Manual v 1 0 20 10 2003 6 ...

Page 7: ...immer channel 1 4 B Dimmer channel 5 8 C Dimmer channel 9 12 D ceramic fuse 6 3 A E Blower F Glass fuse 400mA G Output 7 12 H Output 1 6 I Power input 3 x 230VAC IES EC24 EC12 dimmer pack Operators Manual v 1 0 20 10 2003 7 ...

Page 8: ... Size 483mm x 93mm x 280mm Weight 6 0kg connectors Supply connection 5 x 4mm 2 cable output sockets 12 6 x 2 Output type HAN E 16F Harting product ref EC12 EC24 Control connectors in and out XLR 5 DMX data pins 2 3 Data pins 4 5 control data Control signal DMX 512 4 wire DMX and DATA bi directional data Max level preset 30 0 100 full Min level preset 0 0 29 9 Response time 0 00 secs 9 9 secs up an...

Page 9: ...12 24 no 9602 9804 Conforms to the following product Specifications Emission EN 50081 1 EN 50081 2 EN 55011 EN 55014 Immunity EN 50082 1 EN 50082 2 EN 55024 2 6 kV Contact discharge 8 kV Air discharge EN 55024 3 3 V m EN 55024 4 1 kV Signal lines 2 kV Power lines Supplementary information The product complies with the EMC Directive 89 336 EEC Veenendaal December 2000 J H D de Jonge Technical Manag...