4. DEL-H MENU SETTINGS* 

 

*To enter DEL-H menu press 

DEL

 and 

H

 for 

5seconds. 
 

4.1 ADJUSTING MINIMUM OUTPUT 

By default the adjustment of the minimum 
(PREHEAT) is selected after activation of the Del H 
menu. The minimum output can now be set using H 
and U keys below the display. The minimum output  
can be set to any value between 0% and 29,9% of 
the maximum output. Information thus set is 
immediately stored in the dimmer. To leave this 
menu a channel button must be pressed. To make 
other alterations within the function available in the 
Del  H menu, select function using del, min or max 
key.   

4.2 ADJUSTING MAXIMUM OUTPUT 

After activation of the Del H menu, selection of 
maximum output is done by pressing the max key. 
The maximum output can now be set using the H, T 
and U keys below the display. The maximum output 
can be set to any value between 30% and 99,9% 
(99% is 100%) of the maximum output. Information 
thus is set immediality stored in the dimmer. To 
leave this menu a channel button must be pressed. 
To make other alterations within the functions 
available in the Del H menu, select function using 
del, min or max key. 

4.3 SELECT  SOLIDSTATE FUNCTION 

Each dimmer channel can function as a dimmer or 
as a switch, solid-state channel  (zero crossing). 
To select the switch function enter the maximum 
channel output adjustment using the key sequence 
del H and max. The switch function is active if the 
maximum output is set to 100%. Adjust the display 
until it indicates until it indicates 99,9. Now press the 
U key. The display will show 1-0 indicating that the 
switch function is active. To deselect the switch 
function simply set the maximum output level to a 
value between 30% and 99,9%. 
 
 
 
 
 
 
 
 
 
 
 
 

4.4 ADJUSTING DELAY TIMES 

The delay (response-)time for each dimmer is the 
time it takes for a dimmer channel to travel fro 0% to 
100%. The time value influences dimming delay up 
and down with the same setting. After activation of 
the Del H menu, adjusting of delay times is done by 
pressing the Del key. The delay time output can now 
be set using the T and U keys below the display. 
The delay time set is shown in seconds. The 
minimum delay time is 0,0 seconds. The maximum 
delay time is 9,9 seconds. To leave this menu a 
channel button must be pressed. 
To make other alterations within the functions 
available in the Del H menu, select function using 
del, min, or max key. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

IES EC24 & EC12 dimmer pack Operators’ Manual v. 1.0          

20-10-2003

 4 

Summary of Contents for EC 12

Page 1: ...4 Safety 2 3 Control panel layout 3 4 Function DEL H MENU 4 4 1 Adjusting minimum output 4 4 2 Adjusting maximum output 4 4 3 Select Solid state function 4 4 4 Adjusting delay times 4 5 Function DEL T MENU 5 5 1 Select Dimmer curve 5 5 2 DMX 512 Back up facility 5 6 Function DEL U MENU 5 6 1 Serial communication 5 7 Return to factory settings 6 8 Dimmer overview 7 9 Specifications 8 10 Declaration...

Page 2: ... simply made by fitting the appropriate plug to the load cable 2 3 3 DMX data signal connections The dimmers are controlled using DMX 512 This is connected by a two pair and shield high speed data cable with XLR 5 pin connectors male input female output Pin connections are 1 0V shield 2 DMX 3 DMX 4 DATA 5 DATA The DMX network supports up to 32 PR 6 dimmer packs 192 dimmers in total connected to ea...

Page 3: ...ress the DEL button within 5 seconds the min and max buttons The displayed values should be written including frequency and software number if You might encounter any problem Your dealers need information to assist in an adequate way H Selects the hundreds T Selects the tenths U Selects the units CHANNEL BUTTON AND INDICATION Use these key s to adjust the output level between 0 25 50 75 100 Led s ...

Page 4: ... or max key 4 3 SELECT SOLIDSTATE FUNCTION Each dimmer channel can function as a dimmer or as a switch solid state channel zero crossing To select the switch function enter the maximum channel output adjustment using the key sequence del H and max The switch function is active if the maximum output is set to 100 Adjust the display until it indicates until it indicates 99 9 Now press the U key The ...

Page 5: ...scene is now recorded Channel three Disable off Enable on Exhibition mode This means that a setting can be made with the channel buttons and automatically recorded after 60 seconds This menu can be left by pressing the H button 6 DEL U MENU SETTINGS To enter DEL U menu press DEL and U for 5seconds 6 1 SERIAL COMMUNICATION The Del U menu controls parameters for SERIAL communication with a PC This m...

Page 6: ... RETURN TO FACTORY SETTINGS To return to the factory settings Make the dipswitch setting at the inside off the EC dimmer as below When dipswitch is placed remove power from EC dimmer Plug in Power again Display shows 555 Dipswitch settings normal use Dipswitch setting to reset the EC dimmer IES EC24 EC12 dimmer pack Operators Manual v 1 0 20 10 2003 6 ...

Page 7: ...immer channel 1 4 B Dimmer channel 5 8 C Dimmer channel 9 12 D ceramic fuse 6 3 A E Blower F Glass fuse 400mA G Output 7 12 H Output 1 6 I Power input 3 x 230VAC IES EC24 EC12 dimmer pack Operators Manual v 1 0 20 10 2003 7 ...

Page 8: ... Size 483mm x 93mm x 280mm Weight 6 0kg connectors Supply connection 5 x 4mm 2 cable output sockets 12 6 x 2 Output type HAN E 16F Harting product ref EC12 EC24 Control connectors in and out XLR 5 DMX data pins 2 3 Data pins 4 5 control data Control signal DMX 512 4 wire DMX and DATA bi directional data Max level preset 30 0 100 full Min level preset 0 0 29 9 Response time 0 00 secs 9 9 secs up an...

Page 9: ...12 24 no 9602 9804 Conforms to the following product Specifications Emission EN 50081 1 EN 50081 2 EN 55011 EN 55014 Immunity EN 50082 1 EN 50082 2 EN 55024 2 6 kV Contact discharge 8 kV Air discharge EN 55024 3 3 V m EN 55024 4 1 kV Signal lines 2 kV Power lines Supplementary information The product complies with the EMC Directive 89 336 EEC Veenendaal December 2000 J H D de Jonge Technical Manag...

Reviews: