4. DEL-H MENU SETTINGS*
*To enter DEL-H menu press
DEL
and
H
for
5seconds.
4.1 ADJUSTING MINIMUM OUTPUT
By default the adjustment of the minimum
(PREHEAT) is selected after activation of the Del H
menu. The minimum output can now be set using H
and U keys below the display. The minimum output
can be set to any value between 0% and 29,9% of
the maximum output. Information thus set is
immediately stored in the dimmer. To leave this
menu a channel button must be pressed. To make
other alterations within the function available in the
Del H menu, select function using del, min or max
key.
4.2 ADJUSTING MAXIMUM OUTPUT
After activation of the Del H menu, selection of
maximum output is done by pressing the max key.
The maximum output can now be set using the H, T
and U keys below the display. The maximum output
can be set to any value between 30% and 99,9%
(99% is 100%) of the maximum output. Information
thus is set immediality stored in the dimmer. To
leave this menu a channel button must be pressed.
To make other alterations within the functions
available in the Del H menu, select function using
del, min or max key.
4.3 SELECT SOLIDSTATE FUNCTION
Each dimmer channel can function as a dimmer or
as a switch, solid-state channel (zero crossing).
To select the switch function enter the maximum
channel output adjustment using the key sequence
del H and max. The switch function is active if the
maximum output is set to 100%. Adjust the display
until it indicates until it indicates 99,9. Now press the
U key. The display will show 1-0 indicating that the
switch function is active. To deselect the switch
function simply set the maximum output level to a
value between 30% and 99,9%.
4.4 ADJUSTING DELAY TIMES
The delay (response-)time for each dimmer is the
time it takes for a dimmer channel to travel fro 0% to
100%. The time value influences dimming delay up
and down with the same setting. After activation of
the Del H menu, adjusting of delay times is done by
pressing the Del key. The delay time output can now
be set using the T and U keys below the display.
The delay time set is shown in seconds. The
minimum delay time is 0,0 seconds. The maximum
delay time is 9,9 seconds. To leave this menu a
channel button must be pressed.
To make other alterations within the functions
available in the Del H menu, select function using
del, min, or max key.
IES EC24 & EC12 dimmer pack Operators’ Manual v. 1.0
20-10-2003
4