3. Control panel layout
MAX
The “MAX” function is used to adjust the maximum
level from 40 – 99,9% (=100%) or sets the zero-
crossing solid-state switch. (1-0 displayed).
In normal mode whilst pressed it displays the
software version mode.
MIN
The “MIN” function is used to adjust the minimum
(preheat) level from 0,0 – 29.9%. In normal mode it
indicates the selected mains frequency 50 or 60 Hz.
To select another frequency press “MIN” and while
displaying the frequency press channel 1 until it
changes to the next frequency. This is automatically
stored in Eeprom.
DEL
The “DEL” function is used to adjust the delay time
(response time) from0,0 – 9,9 seconds. In normal
mode whilst pressed it displays the actual delay
time. Monitoring of settings: Press the “DEL” button
within 5 seconds the min and max buttons. The
displayed values should be written, including
frequency and software number if You might
encounter any problem. Your dealers need
information to assist in an adequate way.
H
Selects the hundreds.
T
Selects the tenths.
U
Selects the units.
CHANNEL BUTTON AND INDICATION
Use these key’s to adjust the output level between 0
/ 25 / 50 / 75 / 100%.
Led’s shows the level of the outputs. *
DISPLAY
The display shows the selected start address. This
is the address for the first channel. The remaining
channels are sequential after this address.
The decimal point if blinking indicates the absence
of a valid DMX signal.
Selecting a new start address is simply done by
pressing “H” “T” “U”. This address will automatically
be stored in EEPROM after 30 seconds.
* Led’s on power boards will also show the
output level per channel.
IES EC24 & EC12 dimmer pack Operators’ Manual v. 1.0
20-10-2003