EN
3 - INFORMATION FOR SET UP
KID 80 SIV
3 - Pag. 18 / 23
no.77 Torque reduction in manual mode
Defines the torque value by which the bar
pusher moves in manual mode. This value is
expressed as a percentage of the maximum
torque.
Parameters:
A - Torque reduction in manual mode
Subparameters:
B - Forwards slowly
C - Forwards fast
D - Backwards slowly
E - Backwards fast
no. 78 Toque reduction during bar change
Defines the torque value by which the bar
pusher moves during the bar change cycle in
the phases described by B, C, D, E
subparameters. This value is expressed as a
percentage of the maximum torque.
Parameter:
A - Torque reduction during bar change
Subparameters:
B - From collet entry slowdown to pulse
window end
C - Pulse backwards
D - Facing to limit stop
E - Facing jog
77
no. 77 Torque reduction in manual mode
CURRENT VALUE
Vmax
Forwards slowly
Vmax
Forwards fast
Vmax
Backwards slowly
Vmax
Backwards fast
Vmax
DEFAULT VALUE
PROGRAMMABLE VALUE
Kid 80
Kid 80
A /
/
B 40
/
C 70
/
D 70
/
E 70
/
78
no. 78 Torque reduction during bar change
CURRENT VALUE
Vmax
From "Collet entry slowdown" to "pulse window end"
Vmax
Pulse backwards
Vmax
Facing to the limit stop
Vmax
Facing jog
Vmax
DEFAULT VALUE
PROGRAMMABLE VALUE
Kid 80
Kid 80
A /
/
B 40
/
C 100
/
D 35
/
E
50
/
All manuals and user guides at all-guides.com
Summary of Contents for KID 80-IV Touch
Page 2: ...All manuals and user guides at all guides com...
Page 4: ...All manuals and user guides at all guides com...
Page 14: ...All manuals and user guides at all guides com...
Page 86: ...All manuals and user guides at all guides com...
Page 110: ...All manuals and user guides at all guides com...