prox.pad Installation/Programming Manual
2.3 Unit Capacity
The prox.pad unit can accommodate up to 2,000 users. Each user can have a card/tag, a PIN code, or a card/tag plus a PIN code.
A maximum of 1,000 time-stamped transactions can be stored in the prox.pad unit. Each transaction includes these parameters: Time,
Date, User “slot number,” and event. A complete Transaction Log can be printed to the optional Data Collection Device via the built-
in IR LED. For printing details, see section 2.8. The type of Transaction Log is “First In, First Out.” The oldest transaction gets
deleted when the new one is added.
2.4 Alarm Output Selection
During initial installation, the prox.pad unit’s AUX relay output is wired to trigger ONE of three events. Consequently, the installer
must know which of these events is appropriate for each installation.
●
Alarm Shunt Relay
●
Forced Door Relay
●
Propped Door Relay
Separate instructions and wiring diagrams for each of the above applications are provided later in this chapter.
NOTE:
The capability provided by the internal local sounder (an audible alarm) is separate from the 1A AUX relay. The sounder can
trigger regardless of how the AUX relay is programmed.
Document # 6055676, Rev 2.2, D4b Page 27 of 86