PM-PV-N4551/D5251 User Manual
Page 100
NOTE:
The Watchdog Timer is activated through software. The software
application that activates the Watchdog Timer must also deactivate it
when closed. If the Watchdog Timer is not deactivated, the system will
automatically restart after the Timer has finished its countdown.
EXAMPLE PROGRAM:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
;
MOV
AX, 6F02H
;setting the time-out value
MOV
BL, 30
;time-out value is 48 seconds
INT
15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP
EXIT_AP, 1
;is the application over?
JNE
W_LOOP
;No, restart the application
MOV
AX, 6F02H
;disable Watchdog Timer
MOV
BL, 0
;
INT
15H
;
; EXIT ;
Summary of Contents for PM-PV-N4551/D5251
Page 12: ......
Page 13: ...PM PV N4551 D5251 User Manual Page 1 Chapter 1 1 Introduction...
Page 19: ...PM PV N4551 D5251 User Manual Page 7 Figure 1 6 Dimensions Bottom...
Page 23: ...PM PV N4551 D5251 User Manual Page 11 Chapter 2 2 Unpacking...
Page 27: ...PM PV N4551 D5251 User Manual Page 15 Chapter 3 3 Connectors...
Page 47: ...PM PV N4551 D5251 User Manual Page 35 Chapter 4 4 Installation...
Page 68: ...PM PV N4551 D5251 User Manual Page 56 Chapter 5 5 BIOS...
Page 96: ...PM PV N4551 D5251 User Manual Page 84 Appendix A A Regulatory Compliance...
Page 98: ...PM PV N4551 D5251 User Manual Page 86 B Product Disposal Appendix B...
Page 100: ...PM PV N4551 D5251 User Manual Page 88 Appendix C C BIOS Options...
Page 103: ...PM PV N4551 D5251 User Manual Page 91 Appendix D D Terminology...
Page 107: ...PM PV N4551 D5251 User Manual Page 95 Appendix E E Digital I O Interface...
Page 110: ...PM PV N4551 D5251 User Manual Page 98 Appendix F F Watchdog Timer...
Page 113: ...PM PV N4551 D5251 User Manual Page 101 Appendix G G Hazardous Materials Disclosure...