IEI MiniMax 3 Installation/Programming Manual Section 3: Programming
3.6.5 Programming “Code AND Card” Users
When you are a combination “code and card” user you can present either your card/touch chip first at the front end reader or enter the
code first on the front end keypad. Codes can be from 1 to 6 digit in length in any combination. Refer to table 4 for details on user
types. After you either present your card or enter your code, the red and green LEDs alternate (if unit is equipped with LEDs). This
indicates that the unit is awaiting the second part of the combination before granting access. Once access is granted, the LED turns
solid green (if unit is equipped with LED) and the door unlocks. The programming sequence is as follows:
Action
Command
Enter Program Mode
99 # master code *
Program User
50 # user type # user location # code * repeat code *
<present card>
Exit Program Mode
*
3.6.6 Programming “Code or Card” Users
To program a “Code OR Card” user use command 52. This type of user can use either their code or card to gain access. Codes can be
from 1 to 6 digit in length in any combination. Refer to table4 for details on user types. The programming sequence is as follows:
Action
Command
Enter Program Mode
99 # master code *
Program User
52 # user type # user location # code * repeat code *
<present card>
Exit Program Mode
*
3.6.7 Programming 26-Bit “Card Only” Users via Batch Entry without Presentation
To program a 26-Bit “Card Only” user via batch entry without presentation (without presenting the card to the front end reader) use
command 57. “Batch entry” allows you to enter multiple, sequential 26-Bit format cards into the unit’s memory at one time. Up to
1,998 users can be added this way at one time. (User 1 is reserved for the Master code and user 2 is reserved for the supervisor). When
programming cards with this command, you must program the facility code, using command 32, parameter 2, prior to programming
users.
Action
Command
Enter Program Mode
99 # master code *
Program User
57 # number of users # starting user location # card
number * card number *
Exit Program Mode
*
Document #: 6055672, Rev 1.0 D1c Page 33 of 48
Note:
This programming command applies to Secured Series Front End Keypads and Card Readers only.
Note:
This programming command applies to Wiegand Front Ends only.
Note:
This programming command applies to Secured Series Front End Keypads and Card Readers only.