
IEI MiniMax 3 Installation/Programming Manual Section 3: Programming
3.2 Entering Program Mode and Changing the Master Code
The following sections explains how to enter program mode and change the master code. You also have the option to program a
supervisor user, which allows an additional person to add and delete users.
3.2.1 Entering Program Mode
The first step in programming the Max 3 Door Control Module is to place it into program mode by using the master code, which is
defaulted to 1234.
To place the unit in program mode, press:
99 # Master Code *
When the unit is in program mode the yellow LED flashes slowly.
When you are done programming, to exit program mode press the * key and the yellow LED stops flashing.
If at any point you make a programming error (either press a wrong key or perform a command the unit does not recognize), the unit
produces a program error by turning on the yellow LED solid. To clear a program error, simply press the * key.
Note:
If you don't know the master code press the program button (SW1) on the main circuit board. Momentarily pushing this button
forces the unit into program mode. You then should change the master code immediately.
3.2.2 Changing the Master Code
The master code is stored in user memory location 1 and used to enter program mode. To change the master code use the following
programming sequence:
Action
Command
Enter Program Mode
99 # master code *
Change Master Code
1 # new master code * new master code *
Exit Program Mode
*
Note:
Throughout the programming section the last step is to exit program mode. If you are going to program multiple users or
keypad options, you are not required to exit program mode after each command sequence. You may continue to the next programming
command without exiting program mode. When all your programming is complete, you can then exit program mode by pressing the *
key.
3.2.3 Programming a Supervisor Code
The following table shows how to program a supervisor code. User location 2 is reserved for the supervisor code. This user has access
to only user programming commands and can't change other system related options and parameters.
Action
Command
Enter Program Mode
99 # master code *
Program a Supervisor Code Code
2 # new code * new code *
Exit Program Mode
*
Document #: 6055672, Rev 1.0 D1c Page 29 of 48