IVS-100-BT Advanced Auto Data Server
Page 104
NOTE:
The Watchdog Timer is activated through software. The software
application that activates the Watchdog Timer must also deactivate it
when closed. If the Watchdog Timer is not deactivated, the system will
automatically restart after the Timer has finished its countdown.
EXAMPLE PROGRAM:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
;
MOV
AX, 6F02H
;setting the time-out value
MOV
BL, 30
;time-out value is 48 seconds
INT 15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP
EXIT_AP, 1
;is the application over?
JNE
W_LOOP
;No, restart the application
MOV
AX, 6F02H
;disable Watchdog Timer
MOV BL,
0;
INT 15H
;
; EXIT ;
Summary of Contents for IVS-100-BT
Page 13: ...IVS 100 BT Advanced Auto Data Server Page 1 Chapter 1 1 Introduction ...
Page 21: ...IVS 100 BT Advanced Auto Data Server Page 9 Chapter 2 2 Unpacking ...
Page 26: ...IVS 100 BT Advanced Auto Data Server Page 14 Chapter 3 3 Installation ...
Page 45: ...IVS 100 BT Advanced Auto Data Server Page 33 Chapter 4 4 BIOS ...
Page 74: ...IVS 100 BT Advanced Auto Data Server Page 62 Chapter 5 5 Drivers and Utilities ...
Page 80: ...IVS 100 BT Advanced Auto Data Server Page 68 Chapter 6 6 Maintenance ...
Page 84: ...IVS 100 BT Advanced Auto Data Server Page 72 Chapter 7 7 Interface Connectors ...
Page 96: ...IVS 100 BT Advanced Auto Data Server Page 84 Appendix A A Regulatory Compliance ...
Page 100: ...IVS 100 BT Advanced Auto Data Server Page 88 Appendix B B Safety Precautions ...
Page 105: ...IVS 100 BT Advanced Auto Data Server Page 93 Appendix C C OBD II Reader Command ...
Page 114: ...IVS 100 BT Advanced Auto Data Server Page 102 Appendix D D Watchdog Timer ...
Page 117: ...IVS 100 BT Advanced Auto Data Server Page 105 Appendix E E Hazardous Materials Disclosure ...