IVS-100-BT Advanced Auto Data Server
Page 103
NOTE:
The following discussion applies to DOS. Contact IEI support or visit the IEI
website for drivers for other operating systems.
The Watchdog Timer is a hardware-based timer that attempts to restart the system when it
stops working. The system may stop working because of external EMI or software bugs.
The Watchdog Timer ensures that standalone systems like ATMs will automatically
attempt to restart in the case of system problems.
A BIOS function call (INT 15H) is used to control the Watchdog Timer.
INT 15H:
AH – 6FH Sub-function:
AL – 2:
Sets the Watchdog Timer’s period.
BL:
Time-out value (Its unit-second is dependent on the item “Watchdog
Timer unit select” in CMOS setup).
Table D-1: AH-6FH Sub-function
Call sub-function 2 to set the time-out period of Watchdog Timer first. If the time-out value
is not zero, the Watchdog Timer starts counting down. When the timer value reaches zero,
the system resets. To ensure that this reset condition does not occur, calling sub-function
2 must periodically refresh the Watchdog Timer. However, the watchdog timer is disabled
if the time-out value is set to zero.
A tolerance of at least 10% must be maintained to avoid unknown routines within the
operating system (DOS), such as disk I/O that can be very time-consuming.
Summary of Contents for IVS-100-BT
Page 13: ...IVS 100 BT Advanced Auto Data Server Page 1 Chapter 1 1 Introduction ...
Page 21: ...IVS 100 BT Advanced Auto Data Server Page 9 Chapter 2 2 Unpacking ...
Page 26: ...IVS 100 BT Advanced Auto Data Server Page 14 Chapter 3 3 Installation ...
Page 45: ...IVS 100 BT Advanced Auto Data Server Page 33 Chapter 4 4 BIOS ...
Page 74: ...IVS 100 BT Advanced Auto Data Server Page 62 Chapter 5 5 Drivers and Utilities ...
Page 80: ...IVS 100 BT Advanced Auto Data Server Page 68 Chapter 6 6 Maintenance ...
Page 84: ...IVS 100 BT Advanced Auto Data Server Page 72 Chapter 7 7 Interface Connectors ...
Page 96: ...IVS 100 BT Advanced Auto Data Server Page 84 Appendix A A Regulatory Compliance ...
Page 100: ...IVS 100 BT Advanced Auto Data Server Page 88 Appendix B B Safety Precautions ...
Page 105: ...IVS 100 BT Advanced Auto Data Server Page 93 Appendix C C OBD II Reader Command ...
Page 114: ...IVS 100 BT Advanced Auto Data Server Page 102 Appendix D D Watchdog Timer ...
Page 117: ...IVS 100 BT Advanced Auto Data Server Page 105 Appendix E E Hazardous Materials Disclosure ...