background image

System Specifications 

 

HTB-100-HM170

 

CPU   

Intel® Core™ i7-6822EQ 2.0 GHz   
(up to 2.8 GHz, quad-core, 25W TDP) 
Intel® Core™ i5-6442EQ 1.9 GHz   
(up to 2.7 GHz, quad-core, 25W TDP) 

Chipset 

Intel® HM170 

System Memory   

2 x 260-pin DDR4 SO-DIMM slot (system max. 32 GB) 
Preinstalled one 4.0 GB DDR4 SDRAM SO-DIMM   

Thermal Solution 

Fanless 

Ethernet 

2 x RJ-45 PCIe GbE by Intel® I211 Ethernet controller 

Display 

1 x HDMI 2.0 port (up to 4096x2160 @ 60 Hz) 
1 x VGA port (up to 1920x1200 @ 60 Hz) 

Serial Port 

2 x RS-232 (DB-9 with 2.5 kV isolation) 
2 x RS-232/422/485 (DB-9 with 2.5 kV isolation) 

USB 

2 x USB 2.0 ports 
4 x USB 3.0 ports 

Audio 

Realtek ALC662 5.1-channel High Definition Audio (HDA) 
1 x Audio line-in 
1 x Audio line-out 
1 x Audio mic-in 

Storage 

1 x 2.5” SATA 6Gb/s HDD/SSD bay   

Expansion 

1 x PCIe x16 slot (max. 12 W, 12 V) 
1 x Half-size PCIe Mini card slot (max. 7 W, 3.3 V) 
1 x Full-size PCIe Mini card slot (max. 7 W, 3.3 V) with mSATA 
support (colay with SATA) 
1 x M.2 2230 slot (A-key & E-key; USB or PCIe signal; max. 7 
W, 3.3 V) 

Chassis Construction 

Extruded aluminum alloy   

Power Requirement 

12 V

28 V DC   

Summary of Contents for HTB-100-HM170

Page 1: ...em with Intel Core i7 6822EQ i5 6442EQ Processor Isolated COM Ports GbE LAN HDMI VGA USB 3 0 Audio and RoHS Compliant HTB 100 HM170 Quick Installation Guide Version 1 00 2018 Copyright by IEI Integrat...

Page 2: ...here overlooked details may cause damage to the equipment or result in personal injury Warnings should be taken seriously CAUTION Cautionary messages should be heeded to help reduce the chance of losi...

Page 3: ...rds including IEC 60601 1 V3 1 IEC 60601 1 2 V4 0 ISO 14971 and FCC part 18 Class B making the medical environment more reliable All of the COM ports support 2 5 kV isolation that meets medical standa...

Page 4: ...3 Front Panel Rear Panel...

Page 5: ...A port up to 1920x1200 60 Hz Serial Port 2 x RS 232 DB 9 with 2 5 kV isolation 2 x RS 232 422 485 DB 9 with 2 5 kV isolation USB 2 x USB 2 0 ports 4 x USB 3 0 ports Audio Realtek ALC662 5 1 channel Hi...

Page 6: ...40 C with air flow SSD Storage Transportation 40 C 70 C with air flow SSD Humidity Operation 10 95 non condensing Storage Transportation 10 95 non condensing Pressure Operation 700 hpa 1060 hpa Stora...

Page 7: ...sure the power is off Failing to turn off the power may cause severe injury to the body and or damage to the system Anti static Discharge If a user open the top cover of the medical embedded system to...

Page 8: ...ent over voltage Step 1 Connect the power cord to the power adapter Connect the other end of the power cord to a power source Step 2 Connect the power adapter to the power connector of the HTB 100 HM1...

Page 9: ...nance and Cleaning WARNING 1 For safety reasons turn off the power and unplug the medical embedded system before cleaning 2 If you dropped any material or liquid such as water onto the medical embedde...

Page 10: ...e 1 medical embedded system 1 Power cord 1 Medical grade power adapter 150 W 19 V DC output 1 Grounding cable 1 HDMI cable holder 5 Screws M3 4 for HDD installation 1 Spare screw M2 4 for M 2 installa...

Page 11: ...10 Optional Items The following are optional components which may be separately purchased Item and Part Number Image Cable cover Wi Fi kit P N EMB WIFI KIT02E R10...

Page 12: ...h the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmf...

Page 13: ...RODUCTION MONITORED Component carrying this mark was tested and certified by the independent third party organization T V S D Product Service for its conformity with the safety requirements of EN60601...

Page 14: ...ange Doing so may cause fire and or an electrical shock Use a power cord that matches the voltage of the power outlet which has been approved and complies with the safety standard of your particular c...

Page 15: ...European Directive 2012 19 EU WEEE and must not be disposed of as domestic garbage EU wide legislation as implemented in each Member State requires that waste electrical and electronic products carryi...

Page 16: ...ntact Information IEI Integration Corp Address No 29 Zongxing Rd Xizhi Dist New Taipei City 221 Taiwan Phone 886 2 8691 6798 Fax 886 2 6616 0028 Web Site www ieiworld com Sales Email sales ieiworld co...

Reviews: